Error codes (56)

CodeMeaning
afLow inlet air flow condition detected at installation.f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).f:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).f:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).f:31L2 line voltage errorf:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…f:70No communication between machine control and console electronics.f:71No communication between machine control and console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).F1E1Motor relay stuck on, indicates an ACU problem.F1E3Incorrect controller installed (electric models only); ACU or UI part number…F1E5ACU parameter file missing; parameter memory invalid.F2E1Stuck button on User Interface (depressed for over 20 seconds); only appears in…F2E3UI and ACU model ID parameter mismatch caused by replacement of either the UI…F2E4UI software errorF2E5UI software error
View all 56 error codes
F3E1Exhaust thermistor open or shorted; open if temperature drops below 18°F (>50k…F3E2Moisture sensor strip is open or shorted; only appears in service diagnostic…F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor has shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; this fault code will only appear when in the…F3E7Moisture sensor strip has shorted; this fault code will ONLY appear when in the…F4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E2No voltage detected at heater relay 2; heater 2 failure or connector problem…F4E3Restricted airflow; low airflow that may affect dryer performance.F4E4L2 line voltage error (electric models only); low L2 voltage (less than 50V)…F4E5High limitF6E1Communication error from UI to CCU; communication between the CCU and UI has…F6E2Communication errorF6E3Communication errorFCE0Communication error between ECM and CCU (model WEL98 only).FCE1Communication error from dryer to wireless router (model WEL98 only).FCE2Wireless router cannot communicate with the internet (model WEL98 only).FCE3Antenna A (J2) is bad (model WEL98 only).FCE4Antenna B (J11) is bad (model WEL98 only).FCE5Current Transformer A not functioning at J12 (model WEL98 only).FCE6Current Transformer B not functioning at J12 (model WEL98 only).FCE7Provisioning failureLLow L2 voltage (less than 50V) detected at the CCU; displayed on models 4000…l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.

Service modes (24)

  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Customer-Focused Drying Modes Adjustment["Activate the Diagnostic Test Mode.","Select the Component Activation option.","Select…
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS or DRY LEVEL…
  • Diagnostic Test Mode["Ensure the dryer is not currently running a cycle (in-progress screen should not be…
  • Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Fault Code Display / ClearFrom Service Diagnostic Mode
  • Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
  • Inlet Air Flow Test (Electric Models Only)["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Air Flow'…
  • Install Diagnostics["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Key Activation & Encoder Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
  • Line Voltage Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Press the 'Line…
  • Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds: Press…
  • Manual Diagnostic Test Mode["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
  • Manual Diagnostic Test Mode (Component Activation)["Perform steps 1 and 2 of Activating the Diagnostic Test Mode.","Select the Component Activation…
  • Manual Load Test["Enter the Diagnostic Test Mode.","Select the Component Activation option.","Select individual…
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Service Test Mode["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
  • User Interface Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.