Error codes (49)
CodeMeaning
afLow inlet air flow condition detected at installation (Amana models only).C-81Over temperature.C-82Over temperature.C-83Temperature sensor stuck.F-12Coil under current.F-21Supply power frequency error.F-25Stuck fan on Induction Power System (IPS) (right or left side fan, depending on…F-36Temperature sensor is not working.F-37Temperature sensor is not working.F-40Induction Power System (IPS) failure.F-42Power supply error.F-43Under voltage.F-47Power supply from Induction Power Control (IPC) to User Interface is missing or…F-56Wrong or invalid configuration.F-58Wrong or invalid configuration (IPS).F-60UI does not work.f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20Heater failuref:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (Amana models only, appears ONLY in Diagnostic Test…f:25Inlet thermistor is shorted (Amana models only, appears ONLY in Diagnostic Test…f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (Amana models only, appears ONLY in…f:31L2 line voltage errorf:50Water valve failuref:70No communication between the machine control and the console electronics.View all 49 error codes
f:71No communication between the machine control and the console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).F1E0EEPROM communication error.F2E0Keypad disconnected.F2E1Stuck keypad.F3E0Main oven sensor open or shorted.F3E2Drawer sensor open or shorted.F6E1Over temperature.F8E0Cooling fan speed too low.F8E2Cooling fan speed too high.F9E0Miswired.l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (9)
- Clear All Error CodesEnter Diagnostic Mode by pressing CANCEL>CANCEL>START within 5 seconds
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Diagnostic Test Mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only Done/Dry/Clothes…
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Manual Load Test1. Dryer must be in standby mode. 2. Select any one button except Pause/Cancel and Controls…