Model reference
Dacor L65483
Oven
1 document62 error codes7 service modes
Available documentation
Service Manual
- Discovery Wall Oven Service Manual150 pg
MyPros+ Max
Diagnose your Dacor L65483.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (62)
CodeMeaning
C01Touch panel shorted keyC02Touch panel cancel redundancy failureC72TWI communication errorC73Comm errorC74E2 checksum failure on logic board.C75Redundant strobes on logic board are not the sameC76Config errorC77Config errorC78Light errorC90Power lossL20Lower oven over temperatureL21Lower oven clean over temperatureL22Lower oven over temperatureL23Lower oven ambient over temperatureL24Lower oven ambient temperature probe openL25Lower oven ambient temperature probe shortedL30Lower oven temp sensor open probe 1L31Lower oven temp sensor shorted probe 1L32Lower oven temp sensor open probe 2L33Lower oven temp sensor shorted probe 2L34Lower oven temp sensor open probe 3L35Lower oven temp sensor shorted probe 3L40Lower relay board wiggler failureL41Lower relay board A/D errorL42Lower relay board E2 checksum failure.L43Lower relay board no zero crossing (ZC) detected on relay board.L50Lower latch/door failureL51Lower latch phase failureL52Lower latch/door redundant switch failureL53Lower latch/door switch latching failureView all 62 error codes
L54Lower latch/door lock enable failureL55Lower latch motor failureL60Lower cooling fan failureL61Lower cooling fan failureL70Lower comm errorL80Lower meat probe shortedU20Upper oven over temperatureU21Upper/single oven clean over temperatureU22Upper/single oven over temperatureU23Upper/single oven ambient over temperatureU24Upper/single oven ambient temperature probe openU25Upper/single oven ambient temperature probe shortedU30Upper/single oven temp sensor open probe 1U31Upper/single oven temp sensor shorted probe 1U32Upper/single oven temp sensor open probe 2U33Upper/single oven temp sensor shorted probe 2U34Upper/single oven temp sensor open probe 3U35Upper/single oven temp sensor shorted probe 3U40Upper/single relay board wiggler failureU41Upper/single relay board A/D errorU42Upper/single relay board E2 checksum failure.U43Upper/single relay board no zero crossing (ZC) detected on relay board.U50Upper/single latch/door failureU51Upper/single latch phase failureU52Upper/single latch/door redundant switch failureU53Upper/single latch/door switch latching failureU54Upper/single latch/door lock enable failureU55Upper/single latch motor failureU60Upper/single cooling fan failureU61Upper/single cooling fan failureU70Upper/single comm errorU80Upper/single meat probe shorted
Service modes (7)
- Error Codes Screen["From the FACTORY AND SERVICE DIAGNOSTIC HOME SCREEN, press ERROR CODES.","The 20 most recent…
- Factory and Service Diagnostic Mode["With the main power supply to the oven turned on, press and hold the CANCEL/SECURE and # keys at…
- Manual Diagnostic - Inputs["From the MANUAL DIAGNOSTICS screen, press the INPUTS key.","Monitor input values
- Manual Diagnostic - Modes 1["From the MANUAL DIAGNOSTICS screen, press MODES 1.","If servicing a double oven, select upper or…
- Manual Diagnostic - Modes 2["From the MANUAL DIAGNOSTICS screen, press MODES 2.","If servicing a double oven, select upper or…
- Manual Diagnostic - Outputs["From the FACTORY AND SERVICE DIAGNOSTIC HOME SCREEN, press the OUTPUTS key.","If servicing a…
- Service Temp Calibration["From the FACTORY AND SERVICE DIAGNOSTIC HOME SCREEN, press SERVICE TEMP.","If double oven, select…
Full entry steps, exit procedures, and test sequences are available in Max.