1 document11 error codes7 service modes
Available documentation
Service Manual
- Manual De Servicios / Service Manual - Refrigeradores Frost Free DF80/DF80X/DFI80/DI80X124 pg
MyPros+ Max
Diagnose your Electrolux 02612FNA306.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (11)
CodeMeaning
_ _Panel locked indication on DF80/DF80X models when a 127V unit is connected to…dGForced defrost mode during DFI80/DI80X self-test; product enters forced defrost.ErVoltage error displayed on DFI80/DI80X models when a 127V unit is connected to…FdForced defrost mode active during self-test on DF80/DF80X; defrost heater…FoForced operation mode active during self-test on DF80/DF80X; compressor and…LJShow Room mode confirmation displayed on DF80/DF80X for approximately 1 second…locPanel lock confirmation on DF80/DF80X; appears when panel is successfully…PdPull Down mode during DFI80/DI80X self-test; compressor, condenser fan, and…PoDoor open alarm indication on DF80/DF80X models, displayed when door has been…rAWater reservoir needs refilling (DFI80/DI80X); appears 8 minutes after ice…tSTest Service mode indication on DFI80/DI80X display when self-test routine is…Service modes (7)
- Fine Temperature Adjustment - DF80/DF80X["Press AUTO CONTROL and select the VACATION function.","Then press FREEZER TEMPERATURE 5…
- Fine Temperature Adjustment - DFI80/DI80X["Press DRINK EXPRESS and FREEZER TEMPERATURE simultaneously until a beep is heard.","The function…
- Monitor de Autotest (External diagnostic tool) - DFI80/DI80X["Disconnect the refrigerator from the electrical outlet.","Remove the rear cover with a Phillips…
- Self-test (Autotest) - DF80/DF80X["Press the AUTO CONTROL button once and select the VACATION function.","Then press the TURBO…
- Self-test (Autotest) - DFI80/DI80X["Press the VACATION button once.","Then press the TURBO FREEZING button 20 times (no audible…
- Show Room Mode - DF80/DF80X["During the beep of the panel initialization routine, press AUTO CONTROL and FREEZER TEMPERATURE…
- Show Room Mode - DFI80/DI80X["During the first 5 seconds after the panel initialization routine completes, press FRIDGE…