Model reference
Fisher & Paykel E521T
Refrigerator
5 documents18 error codes7 service modes
Available documentation
Service Manual
- Fisher & Paykel 790 ACTIVE SMART REFRIGERATOR FREEZER Service Manual59 pg
Bulletin
- Refrigerator Doors Difficult to Open1 pg
- Refrigeration Service Bulletin2 pg
Service Flash
- 430 Stainless Steel Introduction - Refrigeration Service Bulletin1 pg
- New Control Module1 pg
MyPros+ Max
Diagnose your Fisher & Paykel E521T.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (18)
CodeMeaning
1On the last power up, the power/control module failed its self-test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13Low ambient heater is drawing less current than expected; either the heater or…14Low ambient heater is drawing more current than expected; either there is a…15The PC fan is drawing less current than expected; either the wiring is open…16The PC fan is drawing more current than expected; either the wiring is shorted…17The FC fan is drawing less current than expected; either the wiring is open…18The FC fan is drawing more current than expected; either the wiring is shorted…2The previous 2 defrosts were aborted after 30 minutes.3The resistance of all the temperature sensors is outside the normal range (>…4The resistance of all the temperature sensors is outside the normal range (<…5The resistance of the FC sensor is outside the normal range (> 45K Ohms).6The resistance of the FC sensor is outside the normal range (< 660 Ohms).7The resistance of the evaporator sensor is outside the normal range (> 45K…8The resistance of the evaporator sensor is outside the normal range (< 660…9The resistance of the PC sensor is outside the normal range (> 45K Ohms).Service modes (7)
- data_download1a
- diagnosticPress and hold the MODE button, then press the TEMPERATURE UP button
- input_output_status1a. Press and hold the MODE button (a short beep will sound). 1b. Whilst still holding the MODE…
- manual_defrost1a
- power_control_module_initializationHave the FC door closed and the PC door open, then press any of the buttons on the user interface…
- show_roomEnter diagnostic mode (press MODE and TEMPERATURE UP buttons together), then hold the TEMPERATURE…
- special_option_mode_israelPush and hold the compartment select MODE button on the display board for 10 seconds.
Full entry steps, exit procedures, and test sequences are available in Max.