Model reference
Fisher & Paykel E522B
Refrigerator
40 documents56 error codes25 service modes
Available documentation
Service Manual
- Fisher & Paykel 790 ACTIVE SMART REFRIGERATOR FREEZER Service Manual59 pg
- Electronic 790 Refrigerator / Freezer21 pg
- fisher paykel e522brx5 service manual2 pg
- SERVICE MANUAL ActiveSmart™ Slide-in refrigerator RS90 and RS36 models74 pg
Bulletin
- Fisher & Paykel Service Bulletins October 200711 pg
- General Bulletin - Refrigeration11 pg
- Spare Part - Invertors2 pg
- Improved Gasket Retainer1 pg
- Control Module Box Cover Modifications1 pg
- Modified Twin Duct Chassis Clip1 pg
- Active Smart Elegance Handles1 pg
- Levelling Feet1 pg
- New Designer Handle Bosses1 pg
- Service Bulletin - Diagnosing Dead On Arrivals (DOA)2 pg
- 2008 June USA CA Tech Bulletin Bundle1 pg
- Service Bulletin - DishDrawer Wash Program Selector Button & Refrigeration Ordering Spare Parts7 pg
- FP Bulletins 2073 pg
- Fisher & Paykel Refrigerator E402B E450 E388 E442B E522B RF610 RF540 Service Bulletin - Flat Door Handle Boss1 pg
- Service Bulletin - Range/Cooktop Replacement Burner Electrode & General Bulletin - Refrigeration Electronic Wiring Diagrams38 pg
- Gas Cooktop New Gas Innovalves – Service Version Change / Dishdrawer Pop Top Diaphragm Lid11 pg
- Appliance Serial Numbering System for Imported Products & Leaking Griddle Safety Valve15 pg
- Appliance Serial Numbering System & Service Bulletin - Built-In Oven, Freestanding Ranges, and Outdoor Grills15 pg
- New D3 Door Handles1 pg
- Service Bulletin13 pg
- Refrigeration Service Bulletin2 pg
- FPBulletins408 - Washers & Dryers Change in Models and Product Codes / AquaSmart Size Setting12 pg
Service Flash
- Active Smart Showa Evaporator Introduction4 pg
- Field Fix for Hard to Open Doors1 pg
- 430 Stainless Steel Introduction - Refrigeration Service Bulletin1 pg
- FISHERPAYKELBULLETINS8200715 pg
- FisherPaykelBulletins6200811 pg
- New Control Module1 pg
Installation Guide
- Installation instructions and user guide - Ice & Water refrigerator76 pg
- Installation instructions and user guide US CA (EN) Ice & Water refrigerator144 pg
Other
- G FRFD 07 061 pg
- tbRF061a1 pg
- TBRF056c1 pg
- TBRF052a1 pg
- tbRF059d2 pg
- tbRF0596 pg
MyPros+ Max
Diagnose your Fisher & Paykel E522B.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (56)
CodeMeaning
1On last power up, the power module failed self test.10The resistance of the PC sensors is outside the normal range (<660 Ohms).11The current for the LAH, PC & FC fan is lower than expected.12The current for the LAH, PC & FC fan is higher than expected.13LAH is drawing less current than expected.14LAH is drawing higher current than expected.15PC fan is drawing less current than expected.16PC fan is drawing higher than expected current.17FC fan is drawing less current than expected.18FC fan is drawing higher current than expected.2The previous 2 defrosts were aborted after 40 minutes.20Flapper heater current low.21Flapper current high.22PC2 sensor/Ambient sensor outside limit (>45K Ohms).23PC2 sensor/Ambient sensor outside limit (<660 Ohms).24IM sensor outside limit (>45K Ohms).25IM sensor outside limit (<660 Ohms).26IM Motor timed out.27IM Motor current too high.28IM Water solenoid current high.29IM Water solenoid current low.3The resistance of all the temperature sensors is outside the normal range (>45K…30No display signal.31No display signal.32Display water transistor 1 failure.33Display water transistor 2 failure.34Display water transistor 1 and 2 failure.4The resistance of all the temperature sensors is outside the normal range (<660…40IM solenoid short circuit transistor 1.41IM solenoid short circuit transistor 2.View all 56 error codes
42IM heater is drawing higher current than expected.43IM heater is drawing less current than expected.49Communication error between control module and inverter.5The resistance of the FC sensors is outside the normal range (>45K Ohms).6The resistance of the FC sensors is outside the normal range (<660 Ohms).7The resistance of the defrost sensor is outside the normal range (>45K Ohms).8The resistance of the defrost sensor is outside the normal range (<660 Ohms).9The resistance of the PC sensors is outside the normal range (>45K Ohms).INV-1Inverter module error (LED flashes 1 time on inverter).INV-10Inverter module error (LED flashes 10 times on inverter).INV-11Compressor starts and stops.INV-12Compressor starts and stops.INV-13Over current detected.INV-14Communication error between control module and inverter.INV-15AC input voltage is low.INV-16Inverter module error (LED flashes 16 times on inverter).INV-17Motor bridge temperature above 100°C (212°F).INV-18Inverter PCB over temp.INV-2Inverter module error (LED flashes 2 times on inverter).INV-3Inverter module error (LED flashes 3 times on inverter).INV-4Inverter module error (LED flashes 4 times on inverter).INV-5Inverter module error (LED flashes 5 times on inverter).INV-6Inverter module error (LED flashes 6 times on inverter).INV-7Inverter module error (LED flashes 7 times on inverter).INV-8Compressor cannot start after 6 attempts.INV-9Inverter module error (LED flashes 9 times on inverter).
Service modes (25)
- data_download1a
- diagnosticPress and hold the MODE button, then press the TEMPERATURE UP button
- Diagnostic modePress and hold the UP and DOWN buttons together for 4 seconds
- Disable filter alarmPress and hold UP, KEY LOCK and BOTTLE CHILL together for 4 seconds to toggle On/Off.
- Disable Water Filter WarningPress the COMPARTMENT, ALARM MUTE, and WARMER buttons together for 4 seconds.
- Fault History (Diagnostic mode 8)Enter diagnostic mode and scroll to mode 8 using the UP/DOWN buttons.
- Filter resetPress and hold DOWN and BOTTLE CHILL together for 4 seconds.
- Forced Defrost ModePress the COMPARTMENT and COLDER buttons together for 4 seconds.
- Forced Ice Harvest ModePress the ALARM MUTE, COLDER, and WARMER buttons together for 4 seconds, then close the PC door.
- input_output_status1a. Press and hold the MODE button (a short beep will sound). 1b. Whilst still holding the MODE…
- Input/Output Display (Diagnostic mode 5)1
- Key LockPress and hold UP and KEY LOCK together for 4 seconds to toggle On/Off.
- manual_defrost1a
- Manually force defrostPress and hold DOWN and KEY LOCK together for 4 seconds.
- Manually force harvestPress and hold UP, DOWN and KEY LOCK together for 4 seconds then close the door(s)
- Manually force icemakerPress and hold KEY LOCK and BOTTLE CHILL together for 4 seconds.
- Optical Download (Diagnostic mode 1)1
- Optical Download ModeEnter diagnostic mode (COMPARTMENT + WARMER for 4 seconds), then press the COLDER button
- power_control_module_initializationHave the FC door closed and the PC door open, then press any of the buttons on the user interface…
- Reset Water Filter IconPress the ALARM MUTE and WARMER buttons together for 4 seconds.
- Sabbath modePress and hold UP, DOWN and KEY LOCK together for 4 seconds to toggle On/Off.
- show_roomEnter diagnostic mode (press MODE and TEMPERATURE UP buttons together), then hold the TEMPERATURE…
- Showroom modePress and hold UP, DOWN and BOTTLE CHILL together for 4 seconds to toggle On/Off.
- special_option_mode_israelPush and hold the compartment select MODE button on the display board for 10 seconds.
- Temperature Sensor Display (Diagnostic modes 2, 3, 4, 6, 7)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel refrigerator models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax