Error codes (30)
CodeMeaning
E00No error code present.E11Fill time too long.E21Water not pumping out fast enough.E31Electronic pressure switch failure.E32Pressure sensor calibration problems.E35Pressure sensor indicates water overfill.E41Control board thinks lid switch is open.E42Lid lock device failure.E43Control board fails to lock lid.E44Lid closed sensing failure.E45Lid locked sensing failure.E46Lid lock command sensing failure.E49Lid incongruence between lid closed sensing and lid locked sensing.E4ALid locked triac sensing failure on control board.E52Tachometer signal missing.E53Low voltage to control board.E57High current on inverter.E58High current on motor phase.E59Incongruence between real motor speed and expected motor speed.E5AHigh temperature on heat sink on control board.E5CVoltage too high on control board.E75Valve NTC failure.E91Communication error between UI board and control board.E92Communication error between UI board and control board.E93UI board or control board problem.E94Control board problem.E97UI board or control board problem.EA1Power supply frequency out of limits.EAELine safe relay sensing failure.EF1Clogged drain pump.Service modes (9)
- diagnostic["1. Knobs can be in any position.","2. If unit is unplugged, plug in (Cold Power On) and go to…
- diagnostic_test_0_button_check["With Cycle Selector knob in Normal position
- diagnostic_test_1_hot_water_fill["Turn Cycle Selector knob 1 click clockwise from Normal position.","Lid lock activates and hot…
- diagnostic_test_2_cold_water_fill["Turn Cycle Selector knob 2 clicks clockwise from Normal position.","Cold water solenoid activates…
- diagnostic_test_3_lid_unlock["Turn Cycle Selector knob 3 clicks clockwise from Normal position.","Lid lock deactivates and lid…
- diagnostic_test_4_agitation["Turn Cycle Selector knob 4 clicks clockwise from Normal position.","Lid lock activates, both hot…
- diagnostic_test_5_drain["Turn Cycle Selector knob 5 clicks clockwise from Normal position.","All motor movement stops and…
- diagnostic_test_6_high_spin["Turn Cycle Selector knob 6 clicks clockwise from Normal position.","Drain pump turns on and…
- diagnostic_test_7_error_code_readout["Turn Cycle Selector knob 7 clicks clockwise from Normal position.","Control signals last 5 error…