Model reference
LG LCU340CP
Air Conditioner
2 documents30 error codes3 service modes
Available documentation
Service Manual
- Ceiling Cassette Air Conditioner SERVICE MANUAL61 pg
- Ceiling Cassette Air Conditioner SVC MANUAL (Exploded View)57 pg
MyPros+ Max
Diagnose your LG LCU340CP.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (30)
CodeMeaning
01Indoor room thermistor error (open/short circuit, poor solder, or internal…02Indoor inlet pipe thermistor error (open/short circuit, poor solder, or…03Remote controller communication error (open/short or wrong connection on wired…04Drain pump / float switch error (float switch open when it should be shorted).05Communication error between indoor and outdoor units.06Indoor outlet pipe thermistor error (open/short circuit, poor solder, or…21DC Peak (IPM Fault).22CT2 (Max CT) error.23DC Link Low Voltage.24High/Low Pressure switch or Heatsink switch open.25Low Voltage / Over Voltage on input (below 140VAC or above 300VAC).26DC compressor position error.27PSC Fault Error.28DC Link High Voltage.32Discharge pipe temperature high on inverter compressor (105°C / 221°F).33Discharge pipe temperature high on constant compressor (105°C / 221°F).40CT Sensor open/short.41Inverter discharge pipe thermistor error (open/short).44Outdoor air thermistor error (open/short).45Condenser pipe thermistor error (open/short).46Suction pipe thermistor error (open/short).47Constant discharge pipe thermistor error (open/short).51Capacity error53Signal error between indoor and outdoor units (displayed at outdoor unit).54Phase error.60EEPROM check sum error.61Condenser pipe sensor detected high temperature (65°C / 149°F).62Heat sink sensor detected high temperature (85°C / 185°F).63Condenser pipe temperature low.65Heatsink thermistor error (open/short).Service modes (3)
- Forced OperationAvailable per function list; specific button sequence not detailed in manual.
- Test RunPress the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Forced Operation)Press the room temperature checking button and the down timer button simultaneously for 3 seconds…
Full entry steps, exit procedures, and test sequences are available in Max.