mypros+
Model reference

Maytag MER6741BAS

Range

9 documents58 error codes21 service modes

Available documentation

Tech Sheet

  • Double Oven Electric Range—Technical Information13 pg
    Covers this model

Service Manual

  • Freestanding Double Oven Electric Range85 pg
    Covers this model
  • Service Manual85 pg
    Covers this model
  • Service Manual - Freestanding Double Oven Electric Range85 pg
    Covers this model
  • Maytag Freestanding Double Oven Electric Range Service Manual85 pg
    Covers this model
  • Failure Codes And Wiring Diagrams For Maytag Heritage Gas & Electric Ranges124 pg
    Covers this model

Service Flash

  • Service Pointer - PF Error Code and/or Slow Running Clock5 pg
    Covers this model
  • Technical Bulletin - TDC-0096-B Oven Door Handles Breaking_TDC-0096-B2 pg
    Covers this model

Other

  • TDC 0096 B2 pg
    Covers this model
MyPros+ Max

Diagnose your Maytag MER6741BAS.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (58)

CodeMeaning
1c1cShorted key detected on the control circuit board.1c2cKeyboard tail disconnected; keyboard loop reads improper value.1c31Cancel key circuit problem (upper oven); cancel key reads improper value.1c32Cancel key circuit problem (lower oven); cancel key reads improper value.1c4cMicro communication failure1c5cVcc or ground fault1c6cEEPROM error; no response from EEPROM after 3 tries.1c7cControl not calibrated; calibration value out of range.1c8cCooking program error; CRC invalid.1d11Runaway temperature (>650°F) with door unlocked in upper oven; sensor…1d12Runaway temperature (>650°F) with door unlocked in lower oven; sensor…1d21Runaway temperature (>950°F) with door locked in upper oven; sensor resistance…1d22Runaway temperature (>950°F) with door locked in lower oven; sensor resistance…3d11Upper oven sensor open (resistance >infinite ohms).3d12Lower oven sensor open (resistance >infinite ohms).3d21Upper oven sensor shorted (resistance >0 ohms).3d22Lower oven sensor shorted (resistance >0 ohms).4d11Door switch position failure (upper); door switch not closed when door is…4d12Door switch position failure (lower); door switch not closed when door is…4d21No reverse airflow fan rotation (no or low RPM) when convection cook or clean…4d31Reverse airflow fan is on when it should be off.4d51Door switch circuit failure (upper); door switch not reading open or closed.4d52Door switch circuit failure (lower); door switch not reading open or closed.9d11Latch will not lock (upper oven); lock switch not closed.9d12Latch will not lock (lower oven); lock switch not closed.9d21Latch will not unlock (upper oven); unlock switch not closed.9d22Latch will not unlock (lower oven); unlock switch not closed.9d31Latch state unknown9d32Latch state unknown9d41Unlock state unknown
View all 58 error codes

Service modes (21)

  • 24-Hour Clock Toggle["Press and hold CANCEL and DELAY pads for 3 to 5 seconds.","Press MORE+ or LESS- pads to change."]
  • Child Lockout["Press and hold CANCEL and COOK & HOLD pads for 3 to 5 seconds until beep sounds."]
  • Clock Display Toggle["Press and hold CANCEL and CLOCK pads for 3 to 5 seconds."]
  • Diagnostic Code Display Mode["Apply power to the unit.","Within 30 seconds of powering up, press and hold the MORE+…
  • Diagnostic Code Display Mode (H2 Control - MER6875A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and UPPER BROIL pads for 3…
  • Diagnostic Code Display Mode (H2 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and UPPER BROIL for 3 seconds within 5 minutes…
  • Diagnostic Code Display Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and TIMER pads for 3…
  • Diagnostic Code Display Mode (H3 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and TIMER for 3 seconds within 5 minutes of…
  • Engineering Test Mode["Press BAKE pad.","Enter 100°F using the number pads.","Immediately push and hold BAKE pad for…
  • Factory Default Reset["Press and hold CANCEL and KEEP WARM pads for 3 to 5 seconds."]
  • Oven Temperature Adjustment["Press BAKE pad.","Enter 550 on the digit pad.","Immediately press and hold BAKE pad for 3 to 5…
  • Quick Test Mode["Press and hold the UPPER CANCEL and BROIL pads for 3 seconds.","Once the control has entered…
  • Quick Test Mode - Component ActivationPress and hold UPPER CANCEL and BROIL pads for 3 seconds
  • Quick Test Mode (H2 Control - MER6875A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and UPPER BROIL pads for 3 seconds
  • Quick Test Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and TIMER pads for 3 seconds.
  • Quick Test Setup Options["Enter Quick Test Mode first.","Press the 0 pad.","'Press Desired Pad for Selection' will scroll…
  • Sabbath Mode["Initiate desired bake function first.","Hold CLOCK pad for 3 to 5 seconds to activate Sabbath…
  • Setup Options ModeWhile in Quick Test Mode, press the 0 pad
  • Temperature Display Toggle (°F/°C)["Press and hold CANCEL and BAKE pads for 3 to 5 seconds.","Press MORE+ or LESS- pads to change."]
  • Test Mode["Must be activated within first 5 minutes of power up.","Press BROIL and CANCEL pads for…
  • Test Mode (ERC)Must be activated within the first 5 minutes of power up

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass