Model reference
Maytag MER6765BAW17
Range
3 documents54 error codes11 service modes
Available documentation
Service Manual
- Service Manual85 pg
- Service Manual - Freestanding Double Oven Electric Range85 pg
- Maytag Freestanding Double Oven Electric Range Service Manual85 pg
MyPros+ Max
Diagnose your Maytag MER6765BAW17.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (54)
CodeMeaning
1c1cShorted key detected on the control circuit board.1c2cKeyboard tail disconnected; keyboard loop reads improper value.1c31Cancel key circuit problem (upper oven); cancel key reads improper value.1c32Cancel key circuit problem (lower oven); cancel key reads improper value.1c6cEEPROM error; no response from EEPROM after 3 tries.1c7cControl not calibrated; calibration value out of range.1c8cCooking program error; CRC invalid.1d11Runaway temperature (>650°F) with door unlocked in upper oven; sensor…1d12Runaway temperature (>650°F) with door unlocked in lower oven; sensor…1d21Runaway temperature (>950°F) with door locked in upper oven; sensor resistance…1d22Runaway temperature (>950°F) with door locked in lower oven; sensor resistance…3d11Upper oven sensor open (resistance >infinite ohms).3d12Lower oven sensor open (resistance >infinite ohms).3d21Upper oven sensor shorted (resistance >0 ohms).3d22Lower oven sensor shorted (resistance >0 ohms).4d11Door switch position failure (upper); door switch not closed when door is…4d12Door switch position failure (lower); door switch not closed when door is…4d21No reverse airflow fan rotation (no or low RPM) when convection cook or clean…4d31Reverse airflow fan is on when it should be off.4d51Door switch circuit failure (upper); door switch not reading open or closed.4d52Door switch circuit failure (lower); door switch not reading open or closed.9d11Latch will not lock (upper oven); lock switch not closed.9d12Latch will not lock (lower oven); lock switch not closed.9d21Latch will not unlock (upper oven); unlock switch not closed.9d22Latch will not unlock (lower oven); unlock switch not closed.9d31Latch state unknown9d32Latch state unknownEEControl cannot read EEPROM; unit will shut down.F0-0No fault (default from factory).F1-1Upper oven temperature >650°F with door unlocked.View all 54 error codes
F1-2Lower oven temperature >650°F with door unlocked.F1-3Upper oven temperature >950°F with door locked.F1-4Lower oven temperature >950°F with door locked.F1-5Upper hardware failure within control.F1-6Lower hardware failure within control.F1-7Membrane switch is not responding.F1-8Shorted key in membrane switch.F1-9Internal communication errors within control.F1-AUpper latch switches failure.F1-BLower latch switches failure.F1-CUpper door switch failure.F1-DLower door switch failure.F1-ESensor input not calibrated.F1-HEEPROM error.F1-LTemperatures in ovens are the same for a long period.F1-NInternal voltage on control not working.F3-1Upper sensor is shorted (<100 ohms) or open (>5K ohms).F3-2Lower sensor is shorted (<100 ohms) or open (>5K ohms).F9-1Upper lock switch is not correct.F9-2Upper unlock switch is not correct.F9-3Control does not see upper door lock.F9-4Lower lock switch is not correct.F9-5Lower unlock switch is not correct.F9-6Control does not see lower door lock.
Service modes (11)
- Diagnostic Code Display Mode (H2 Control - MER6875A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and UPPER BROIL pads for 3…
- Diagnostic Code Display Mode (H2 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and UPPER BROIL for 3 seconds within 5 minutes…
- Diagnostic Code Display Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and TIMER pads for 3…
- Diagnostic Code Display Mode (H3 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and TIMER for 3 seconds within 5 minutes of…
- Engineering Test Mode["Press BAKE pad.","Enter 100°F using the number pads.","Immediately push and hold BAKE pad for…
- Quick Test Mode["Press and hold the UPPER CANCEL and BROIL pads for 3 seconds.","Once the control has entered…
- Quick Test Mode (H2 Control - MER6875A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and UPPER BROIL pads for 3 seconds
- Quick Test Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and TIMER pads for 3 seconds.
- Quick Test Setup Options["Enter Quick Test Mode first.","Press the 0 pad.","'Press Desired Pad for Selection' will scroll…
- Setup Options ModeWhile in Quick Test Mode, press the 0 pad
- Test Mode["Must be activated within first 5 minutes of power up.","Press BROIL and CANCEL pads for…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass