Model reference
Maytag MGR6875AS
Range
2 documents54 error codes6 service modes
Available documentation
Service Manual
- Maytag Gemini Freestanding Double Oven Gas Range Service Manual69 pg
Other
- 16023415_1602341569 pg
MyPros+ Max
Diagnose your Maytag MGR6875AS.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (54)
CodeMeaning
1c1cShorted key detected on control circuit board.1c2cKeyboard tail disconnected from control circuit board.1c31Cancel key circuit problem (upper oven cavity).1c32Cancel key circuit problem (lower oven cavity).1c6cEEPROM error1c7cControl not calibrated1c8cCooking program error1d11Runaway temperature (650°F) with door unlocked, upper oven; sensor resistance…1d12Runaway temperature (650°F) with door unlocked, lower oven; sensor resistance…1d21Runaway temperature (950°F) with door locked, upper oven; sensor resistance…1d22Runaway temperature (950°F) with door locked, lower oven; sensor resistance…3d11Oven sensor open (infinite ohms), upper oven.3d12Oven sensor open (infinite ohms), lower oven.3d21Oven sensor shorted (0 ohms), upper oven.3d22Oven sensor shorted (0 ohms), lower oven.4d11Door switch position failure4d12Door switch position failure4d21No reverse airflow fan rotation (no/low RPM).4d31Reverse airflow fan state on when it should be off.4d51Door switch circuit failure4d52Door switch circuit failure9d11Latch will not lock9d12Latch will not lock9d21Latch will not unlock9d22Latch will not unlock9d31Latch state unknown9d32Latch state unknownEEControl cannot read E-PROM; unit will shut down.F0-0No faultF1-1Upper oven temperature exceeds 650°F with door unlocked.View all 54 error codes
F1-2Lower oven temperature exceeds 650°F with door unlocked.F1-3Upper oven temperature exceeds 950°F with door locked.F1-4Lower oven temperature exceeds 950°F with door locked.F1-5Upper hardware failure within control.F1-6Lower hardware failure within control.F1-7Membrane switch is not responding.F1-8Shorted key in membrane switch.F1-9Internal communication errors within control.F1-AUpper latch switches failure.F1-BLower latch switches failure.F1-CUpper door switch failure.F1-DLower door switch failure.F1-ESensor input not calibrated.F1-HEEPROM error.F1-LTemperature in ovens are the same for a long period.F1-NInternal voltage on control not working.F3-1Upper sensor is shorted (<100 ohms) or open (>5K ohms).F3-2Lower sensor is shorted (<100 ohms) or open (>5K ohms).F9-1Upper lock switch is not correct.F9-2Upper unlock switch is not correct.F9-3Control does not see upper door lock.F9-4Lower lock switch is not correct.F9-5Lower unlock switch is not correct.F9-6Control does not see lower door lock.
Service modes (6)
- Diagnostic Code Display Mode (H2 Control - MGR6875AD*)Press and hold the AUTOSET pad for 3 seconds at power-up
- Diagnostic Code Display Mode (H3 Control - MGR6775AD*)Press and hold Upper Cancel and Timer for 3 seconds within 5 minutes of power up.
- Engineering Test Mode (H3 Control - MGR6775AD*)Press BAKE pad, enter 100°F using number pads, immediately push and hold BAKE pad for approximately…
- Quick Test Mode (H2 Control)1
- Setup Options (within Quick Test Mode)While in Quick Test Mode, press the 0 pad
- Test Mode (H3 Control - MGR6775AD*)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass