Model reference
Maytag YMER8800FW1
Range
5 documents42 error codes35 service modes
Available documentation
Tech Sheet
- Tech Manual16 pg
- Fiche technique - Tech Sheet W10667176 Rev A8 pg
- Tech Sheet - W10667169 - Rev C8 pg
Service Manual
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
MyPros+ Max
Diagnose your Maytag YMER8800FW1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (42)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1 E0EEPROM communication error.F1 E5Sensor out of range.F1 E7PCB thermistor open or shorted.F1-E0EEPROM communication error.F1E0Internal board failure (LCC/LCX control).F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2 E0Keypad disconnected.F2 E1Stuck key.F2 E2Cancel key error.F2-E0Keypad disconnected.F2E0Shorted key (LCC/LCX control).F2E1Stuck KeypadF2E2Cancel key error.F3 E0Main oven sensor open or short-circuited.F3 E2Warming drawer sensor open or short-circuited.F3-E0Oven temperature sensor open or short-circuited (measured at P10-1 and P10-2).F3-E2Warming drawer sensor open or shorted.F3E0Oven sensor opened (LCC/LCX control)F3E1Oven sensor shorted (LCC/LCX control).F3E2Bake/Broil range over temperature (LCC/LCX control).F3E3Clean range over temperature (LCC/LCX control).F5 E0Door switch fault.F5-E0Door switch/latch fault (measured at P7-5 and P7-4).F5E0Door and door position switch do not agree during Clean mode (Maxwell/MRC…F5E1Door latch not operating during Clean mode (LCC/LCX control).View all 42 error codes
F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6 E1Over temperature during cook mode.F6 E2Over temperature during clean mode.F6 E3Over temperature (warming drawer).F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Over temperature cookF6E2Over temperature during clean mode (Maxwell/MRC control).F6E3Over temperature in warming drawer (Maxwell/MRC control).F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9E0Mis-wired house or range (Maxwell/MRC control).
Service modes (35)
- Auto TestFrom service mode (CANCEL > CANCEL > START), press up arrow / '+' / '3' to scroll to 'AUTO TEST'…
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- CONTROL RESETFrom service mode, scroll to step 6 'CONTROL RESET'.
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Auto Test)1
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (MRC Control)Press CANCEL > CANCEL > START
- Diagnostics Mode (Service Mode Entry)Press CANCEL > CANCEL > START
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- DISPLAYFrom service mode, scroll to step 5 'DISPLAY'.
- ENG MODEPress CANCEL > CANCEL > START to enter Service Mode
- ENG MODE (Engineering Mode)From service mode, scroll to step 2 'ENG MODE'
- FAULTSFrom service mode, scroll to step 7 'FAULTS'.
- MRC Control Module Diagnostic Mode / Service ModePress CANCEL > CANCEL > START in sequence
- MRC Control Module Diagnostics / Service ModePress CANCEL > CANCEL > START to enter service mode
- RELAY USAGEFrom service mode, scroll to step 8 'RELAY USAGE'.
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature Adjustment1
- Temperature Offset AdjustmentPress OVEN LIGHT for 5 seconds
- TEST MODEFrom service mode, scroll to step 3 'TEST MODE'.
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
- TEST ON - Relay ControlEnter service mode (CANCEL > CANCEL > START)
- TEST ON (Relay Checks)Press CANCEL > CANCEL > START. Upon entry, 'TEST ON' is displayed. Use specific key presses to…
- TEST ON (Relay Test Mode)Entered immediately upon accessing Service Mode (CANCEL>CANCEL>START)
- USAGEFrom service mode, scroll to step 1 'USAGE'.
- VERSIONFrom service mode, scroll to step 4 'VERSION'.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax