24 documents14 error codes4 service modes
Available documentation
Service Manual
- Top Load Washer Service Manual99 pg
Service Flash
- Vibration in Spin Cycle - Repair Tip3 pg
- Maytag TL Bulletin TDL 0086 B8 pg
- Technical Bulletin - ITDL-0009-S When to add Pump Sleeve to pump_ITDL-0009-S1 pg
- Technical Bulletin - ITDL-0031-B New water pump design1 pg
Bulletin
- Technical Bulletin - TDL-0084-B Machine vibration2 pg
- Technical Bulletin - TDL-0084-B-French Machine vibration2 pg
- Technical Bulletin - Poor spin or clothes soaking wet2 pg
- Technical Bulletin TDL-0134-S2 pg
- Technical Bulletin - TDL-0026-B Tub to Pump Hose improvement1 pg
- Technical Bulletin - TDL-0013-B New sheet metal transmission cover1 pg
- Technical Bulletin - New sheet metal transmission cover1 pg
- Technical Bulletin - Washer Vibration2 pg
- Technical Bulletin - Machine vibration2 pg
- Technical Bulletin - Wash Basket Leans to One Side4 pg
- Technical Bulletin - Wash basket leans to one side2 pg
- Technical Bulletin - TDL-0013.B1 pg
- Technical Bulletin - ITDL-0009-S When to add Pump Sleeve to pump1 pg
- Technical Bulletin - Transmission and Seal design change8 pg
- Maytag PAV Trans Bulletin TDL 0017B B8 pg
- Technical Bulletin - New Hub and Seal8 pg
Job Aid
- Instruction Sheet - Herrin/Atlantis Platform Triple Lip Seal and Bearing Kit16 pg
Other
- TDL 0026 B1 pg
- ITDL 0014 B8 pg
MyPros+ Max
Diagnose your Maytag HAV1200ARW.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (14)
CodeMeaning
0No code present.1Power failure detected.15Thermistor out of range.16Thermistor possible open.17Thermistor possible short.18Motor thermal protector opened more than 5 times during a cycle.19Motor thermal protector opened.21Fill time exceeded 18 minutes.22Fill time less than 2 seconds.24Incorrect rotary switch position seen.25Rotary Switch 1 left of encoder failed at startup.26Rotary Switch 2 left of encoder failed at startup.28Rotary Switch 3 left of encoder failed at startup.31Model ID Unknown, Default model of 31 used.Service modes (4)
- Console Switch Test1
- Display/Clear Service Codes1
- Service Cycle1. Enter Service Mode. 2. Set Cycle Selection Knob to 'Regular' and press knob. Steps: Press knob
- Service Mode (Electronic Controls)1
Full entry steps, exit procedures, and test sequences are available in Max.