Miele G2732

Dishwasher

1 document27 error codes3 service modes

Available documentation

Service Manual

  • Technical Information G 2732 Excella II Dishwashers94 pg
    Covers this model
MyPros+ Max

Diagnose your Miele G2732.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (27)

CodeMeaning
F01Water/heating NTC temperature sensor R30 or its leads are short-circuited…F02Water/heating NTC temperature sensor R30 or its leads are open-circuited…F11Drainage fault; water present in appliance is not being drained offF12Water intake fault at start of step; during the first 5 seconds of any water…F13Water intake fault at end of step; the desired number of flow meter pulses has…F14Water intake fault at heater pressure switch; with circulation pump operating…F18Flow meter stationary state monitor B3/4; unexpected pulses detected from the…F19Flow meter B3/4 stiff and not turning freely; satisfactory test routines to…F24Heater relay contact fault; when circulation pump is not operating, supply…F25Desired temperature fault; during heating, the desired temperature was not…F26Boiling protection; temperature at NTC temperature sensor has exceeded 194°F…F40Electronic fault; the electronic has a hardware fault that cannot be repaired…F42Line frequency registration fault; the line frequency cannot be clearly…F47Interface fault between Selection-display module (BAE) and Control-power module…F51Heater pressure switch fault; one second after program start, heater relay K1/1…F52Heater pressure switch has reset during heating; program continues without…F63Slide shutter fault; even though the slide shutter motor has been activated…F68Circulation pump operating after switch-off; the frequency converter registers…F70Float switch fault (WaterProof System activated); water detected in drip pan…F78Circulation pump fault; interrupted connection between electronic and door…F79Circulation pump interaction fault; faulty interaction between the frequency…F84Slide shutter positioning fault; position switch, synchronous motor drive, or…F85Slide shutter signal change fault; a signal change detected at the position…F86Lid contactF87Sensor softener fault; an emergency program operates with fixed reactivation…F88Turbidity sensor fault; false or no values from turbidity sensorF91Load size registration inactive; water intake block operates with default water…

Service modes (3)

  • Component Test["Enter Service Mode (see above).","Select 'Component' with cursor buttons.","Press OK.","Activate…
  • Service Mode (Diagnostics)["Close the door.","Switch off the appliance.","Press and hold the Start button.","Switch on the…
  • Service Programming["Close the door.","Switch off the appliance.","Press and hold the Start button.","Switch on the…

Full entry steps, exit procedures, and test sequences are available in Max.