4 documents38 error codes8 service modes

Available documentation

Service Manual

  • Service Manual - Gas Electric Refrigerators60 pg
    Covers this model
  • Manuel d'entretien - Réfrigérateurs au gaz et à l'électricité60 pg
    Covers this model
  • Manual de servicio - Refrigeradores eléctricos y de gas60 pg
    Covers this model
  • Cooling Unit Replacement Service Kits36 pg
    Covers this model
MyPros+ Max

Diagnose your Norcold N7V.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (38)

CodeMeaning
AC HEAC heater faultAC rEAC heater relay on the main control board (power board) is stuck closed…Blink 1AC heating element faultBlink 10Loss of communication between user interface (controls) and main control board…Blink 2Internal control fault detected by main control board (power board).Blink 3Current limiter circuit on main control board (power board) is open.Blink 4AC heating element relay on main control board stuck in closed/activated…Blink 5Flame detected at burner when there should be none; gas valve mechanically…Blink 8DC supply voltage to refrigerator is too low.Blink 9DC supply voltage to refrigerator is too high.dc HEDC heater faultdc rEDC heater relay (K1 on the DC Board) contacts are stuck closed (N7LX/N8LX…FL --A flame is sensed at the burner when there should be none present; gas valve is…Flash 1AC heater faultFlash 10Communications between the user interface (controls) and the main control board…Flash 2Internal control fault detected by the main control board (power board).Flash 3On the main control board (power board), the limit circuit is open.Flash 4The AC heater relay on the main control board (power board) is stuck closed.Flash 5A flame is sensed at the burner when there should be none present; gas valve is…Flash 6Problem relating to the DC heater (3-way models only).Flash 7Fault within the refrigerator electronic controls (3-way models only).Flash 8The DC input voltage to the refrigerator is too low.Flash 9The DC input voltage to the refrigerator is too high.HI dcDC input voltage to the refrigerator is too high (N7LX/N8LX models).Lo dcDC input voltage to the refrigerator is low; cooling is to continue (N7LX/N8LX…Lo dc (alarm)DC input voltage to the refrigerator is too low; either GAS MODE or DC MODE…Lo dc (with alarm)DC supply voltage too low; gas mode and/or DC mode (3-way) inhibited…no ACAC voltage is not available to the refrigerator (N7LX/N8LX models).no dtCommunications between the user interface (controls) and the main control board…no FLThe burner did not ignite or re-ignite; no flame sensed at burner when there…
View all 38 error codes

Service modes (8)

  • Diagnostic Mode (N7LX and N8LX models)1
  • Diagnostic Mode (N7LX/N8LX models)Press and hold both the MODE and Temperature Adjustment buttons simultaneously for 5 seconds
  • Diagnostic Mode (N7LX/N8LX)Press and hold MODE and Temperature buttons simultaneously for 5 seconds
  • Erase Fault History (within Diagnostic Mode, Screen 6, N7LX/N8LX)1
  • Manual Gas Propane Mode Toggle (N7V/N8V)From Auto mode
  • Mode Change (N7V and N8V - Auto to Manual Gas)Touch and hold the Power ON/OFF button for between 20-23 seconds
  • Temperature Set Mode (N7V and N8V models)1
  • Temperature Setting Mode (N7V/N8V)Press and hold On/Off button

Full entry steps, exit procedures, and test sequences are available in Max.