1 document12 error codes1 service mode
Available documentation
Service Manual
- Slide In Gas Ranges Service Manual35 pg
MyPros+ Max
Diagnose your Samsung NV51CG700SSRAA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (12)
CodeMeaning
C-20Oven temperature sensor is open or shorted when the oven is operating.C-21Internal oven temperature rises abnormally high during operation.C-23Temp probe (meat probe) sensor is shorted when oven is operating.C-30PCB temperature sensor is open or shorted when the oven is operating.C-31PCB temperature rises abnormally high.C-70Steam sensor is open or shorted when the steam mode is operating.C-72Drain system problem; water level sensor senses water remaining after maximum…C-A2Cooling motor is operating abnormally.C-d0Keys are shorted on the keypad.C-d5Door lock is mispositioned or door locking error.C-F0Communication between the Main PCB and Sub PCB is interrupted.C-F2Communication between the Main PCB and Touch PCB is interrupted.Service modes (1)
- diagnostic / error display mode["Touch FLEX UPPER and FLEX LOWER simultaneously for 5 seconds.","Information is displayed on…