Model reference
Samsung RS257BASB
Refrigerator
5 documents23 error codes8 service modes
Available documentation
Service Manual
- SAMSUNG Home Appliance Service Technical Service Guide - Side-By-Side Refrigerator66 pg
- SAMSUNG Home Appliance Service Technical Service Guide - Side-by-Side Refrigerator75 pg
- SAMSUNG Home Appliance Service - Side-by-Side Refrigerator Technical Service Guide75 pg
- SAMSUNG Home Appliance Service - Side-by-Side Refrigerator Technical Service Guide3 pg
Bulletin
- Service Bulletin - Capillary tube is not inserted to the dryer correctly this creates a Low or No Cool condition2 pg
MyPros+ Max
Diagnose your Samsung RS257BASB.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (23)
CodeMeaning
01Ice Maker sensor failure02Refrigerator sensor failure03Refrigerator defrost sensor failure04Refrigerator fan motor operation failure05Ice Maker function error06CoolSelect Zone sensor failure07Refrigerator defrost error08Ambient air sensor failure09Freezer sensor failure1Ice maker sensor error10Freezer defrost sensor failure11Freezer fan motor operation failure12Condenser fan motor operation failure13Freezer defrost error14PLC (Power Line Communication) error2Refrigerator sensor error3Refrigerator defrost sensor error4Refrigerator fan motor operation error5Ice maker function error6CoolSelect Zone sensor error7Refrigerator defrost error8Ambient air sensor error9Freezer sensor errorService modes (8)
- Child LockPress Power Cool button and Fridge button simultaneously for 3 seconds
- Exhibition ModePress Power Freeze and Freezer Temp
- Forced Operation (Pull-down / R-Defrost / R,F-Defrost / Cancellation)Press Power Freeze and Fridge Temp. buttons simultaneously for 8 seconds to enter ready mode. Then…
- Ice Maker TestPress the knob (Test Switch) on the ice maker for 1.5 seconds.
- Load Operation CheckIn normal operation, press Power Freeze and Power Cool buttons simultaneously for 6 seconds…
- Self-Diagnostics (Initial Power On)Automatically performed within 1 second of initial power on
- Self-Diagnostics (Normal Operation)Press Power Freeze and Power Cool buttons simultaneously for 8 seconds until audible tone sounds.
- Set Point ShiftPress Freezer Temp
Full entry steps, exit procedures, and test sequences are available in Max.
Related Samsung refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands