mypros+
Model reference

Sub-Zero ICBBI-42UFDID/S/PH

Refrigerator

5 documents132 error codes13 service modes

Available documentation

Service Manual

  • Sub-Zero Service Manual: ICBBI-42UFDID — Service Manual176 pg
    Covers this model

Parts Manual

  • Sub-Zero Classic Enhancements (7019017): Serials 4100000 to 4199999 — Parts Manual90 pg
    Covers this model
  • Sub-Zero Original (7011903): Prior to Serial 4100000 — Parts Manual90 pg
    Covers this model
  • Sub-Zero Classic (formerly Built-In) Enhancements (7040321): After Serial 4380000 — Parts Manual89 pg
    Covers this model
  • Sub-Zero Classic Enhancements (7025631): Serials 4200000 to 4379999 — Parts Manual77 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ICBBI-42UFDID/S/PH.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (132)

CodeMeaning
10 1 00Refrigerator cabinet thermistor open.10 1 01Refrigerator cabinet thermistor shorted.10 1 02Refrigerator cabinet thermistor unstable.10 2 00Freezer cabinet thermistor open.10 2 01Freezer cabinet thermistor shorted.10 2 02Freezer cabinet thermistor unstable.10 3 00Condenser thermistor open.10 3 01Condenser thermistor shorted.10 3 02Condenser thermistor unstable.10 7 00Ambient thermistor open.10 7 01Ambient thermistor shorted.10 7 02Ambient thermistor unstable.10 F 00Freezer evaporator thermistor open.10 F 01Freezer evaporator thermistor shorted.10 F 02Freezer evaporator thermistor unstable.10 r 00Refrigerator evaporator thermistor open.10 r 01Refrigerator evaporator thermistor shorted.10 r 02Refrigerator evaporator thermistor unstable.10 r 09Refrigerator evaporator thermistor read higher than cabinet thermistor by at…15 1 00Refrigerator compressor relay stuck open; no power to compressor.15 1 01Refrigerator compressor relay stuck closed; power to compressor at all times.15 2 00Freezer compressor relay stuck open; no power to compressor.15 2 01Freezer compressor relay stuck closed; power to compressor at all times.15 4 00Defrost relay is stuck open; no power to defrost heater.15 4 01Defrost relay is stuck closed; power to defrost heater at all times.15 8 00Ice maker relay is stuck open; no power to ice maker.15 8 01Ice maker relay is stuck closed; power to ice maker at all times.15 8 10Ice accessories relay is stuck open; no power to ice accessories.15 8 11Ice accessories relay is stuck closed; power to ice accessories at all times.15 9 00Dispenser auger relay is stuck open; no power to auger.
View all 132 error codes
15 9 01Auger relay is stuck closed; power to auger at all times.15 L 00Main lights relay is stuck open; power to lights at all times.15 L 01Main lights relay is stuck closed; no power to lights.15 U 00Water valve relay is stuck open; no power to water valve.15 U 01Water valve relay is stuck closed; power to water valve at all times.15 U 10Water check valve relay is stuck open; no power to water check valve.15 U 11Water check valve relay is stuck closed; power to water check valve at all…20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Mis-wired bi-metal; normal temperatures during defrost but inappropriate…20 2 06Mis-wired bi-metal; high temperatures during defrost and inappropriate response…20 2 07Defrost bi-metal error.20 2 50Defrost heater open.30 8 00Ice accessories open circuit.30 8 05No signal from ice maker for fill.30 8 10Ice maker open circuit.30 8 30Water valves not opened, but water flow observed by the flow meter.30 9 01Bulk ice switch stuck closed; pressed or closed for more than five seconds with…30 9 10Dispenser auger open.30 9 80No communications with door dispenser.30 9 86Dispenser chute motor timed out; chute motor failed to reach open or closed…30 U 00Water valve open.30 U 10Dispenser water valve open.30 U 20Water check valve open circuit; solenoid is open.35 3 00This code is inactive35 A 36Air filter fan is not connected properly or not functioning.35 A 37Air filter fan connection or short issue.35 F 33Freezer evaporator fan unable to achieve full speed.35 F 34Freezer evaporator fan shorted; runs faster than speed setting.35 r 33Refrigerator evaporator fan unable to achieve full speed.35 r 34Refrigerator evaporator fan shorted; runs faster than speed setting.40 1 38Refrigerator stepper valve communication fault.40 1 40Excessive refrigerator compressor run time.40 2 38Freezer stepper valve communication fault.40 2 40Excessive freezer compressor run time.40 8 40Ice maker ran for maximum fill time without achieving necessary volume.40 9 40Dispenser active for maximum fill time.40 b 38Baffle stepper communication fault.44 0 00Glass door heater open circuit.44 0 01Glass door heater short circuit.44 9 42One-watt glass well heater not detected.44 9 43Four-watt glass well heater not detected.45 1 00Main refrigerator lights open circuit.45 1 01Main refrigerator lights short circuit.45 2 00Main freezer lights open circuit.45 2 01Main freezer lights short circuit.45 A 45Air filter light burned out.45 L 00Accent lights open circuit.45 L 01Accent lights short circuit.50 U 80Water flow meter not detected.50 U 86Water flow meter detected low flow.50 U 87Water flow meter did not detect flow.60 1 02Refrigerator variable speed compressor communication error.60 1 38Refrigerator variable speed compressor communication error.60 1 60No refrigerator compressor load detected.60 2 02Freezer variable speed compressor communication error.60 2 38Freezer variable speed compressor communication error.60 2 60No freezer compressor load detected.90 0 70Flash failure.90 0 71Flash failure.90 0 72Flash failure.90 0 73Flash failure.90 0 74Flash failure.90 0 75Flash failure.90 0 81Microcontroller fault.90 0 90Microcontroller fault.90 0 92Microcontroller fault.90 0 93Microcontroller fault.90 3 55Condenser fan triac open.90 3 56Condenser fan triac shorted.90 5 0112 VDC fan power output fault.90 5 38Key shorted or damaged on display.90 5 39Key shorted or damaged on display.90 5 44Glass door heater output fault.90 5 80No keypad communications.90 5 85Display failure.90 5 95Key shorted or damaged on display.90 5 96Display microcontroller problem.90 5 97Display error.90 5 99Initialization fault.90 9 80No communications with door dispenser.90 A 38Air filter fan output fault on control board.90 A 56This code is inactive90 b 80No stepper microcommunication.90 F 38Freezer evaporator fan output fault on control board.90 H 80Communication problems on control board.90 H 82Intermittent communications on control board.90 H 83Communication problems on control board.90 H 84Check if accent lights are working.90 L 38Display failure.90 r 38Refrigerator evaporator fan output fault.95 1 00Refrigerator compressor microprocessor pin stuck in off position.95 1 01Refrigerator compressor microprocessor pin stuck in on position.95 1 25Refrigerator evaporator not cooling properly when compressor is on.95 2 00Freezer compressor microprocessor pin stuck in off position.95 2 01Freezer compressor microprocessor pin stuck in on position.95 2 25Freezer evaporator not cooling properly when compressor is on.98 0 98Brownout conditions were detected.d0 0rFrench door model internal dispenser door left open for more than five minutes…EERefrigerator or freezer cabinet thermistor is open or shorted.H2 L03.8 liters of water dispensed in 15 minutes or dispenser water valve energized…L0 CControl panel locked because display icons were tapped while the door was…

Service modes (13)

  • contrast_adjustCan be accessed only after the unit has been on for one minute
  • diagnosticTouch and hold a temperature up/down arrow, then touch the power icon
  • fault_code_clearingTouch and hold the power icon for 15 seconds
  • fault_code_recallEnter diagnostic mode (touch and hold a temperature arrow, then touch power, release both)
  • manual_component_activationEnter diagnostic mode
  • manual_freezer_evaporator_defrostUnit must be on
  • manual_zone_disableTurn the unit off by tapping power
  • sabbathTurn the unit off by tapping power
  • self_testEnter diagnostic mode first
  • showroomTurn off the unit by tapping power
  • temperature_log_recallEnter diagnostic mode and scroll to the desired thermistor
  • temperature_units_selectionMust be initiated within the first minute after switching the unit on
  • tone_adjustEnter contrast adjust mode first

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started