9 documents60 error codes28 service modes

Available documentation

Tech Sheet

  • Fiche technique - Tech Sheet W104413076 pg
    Covers this model
  • Tech Sheet - W10392955 - Rev A (MRC-FR)8 pg
    Covers this model
  • Tech Sheet - W10441306 - Rev A6 pg
    Covers this model
  • Tech Sheet - W10392954 - Rev A (MRC)8 pg
    Covers this model

Service Flash

  • Technical Service Pointer10 pg
    Covers this model

Tech Tip

  • Oven Cleaning Quick Reference Guide2 pg
    Covers this model

Installation Guide

  • Installation Instructions16 pg
    Covers this model
  • Instruction Sheet2 pg
    Covers this model

Quick Reference

  • Quick Reference Manual2 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool YMIR8890AS0.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (60)

CodeMeaning
C-81Over temperature condition detected.C-82Over temperature condition detected.F-12Coil under current detected on a burner.F-12 E-12Coil under currentF-21Supply power frequency is incorrect.F-21 E-00Supply power frequency errorF-25Stuck fan on power control board (right or left side fan, depending on which…F-25 E-25Stuck fan on power control board (right or left side fan, depending on which…F-36Temperature sensor is not working.F-36 E-36Temperature sensor is not working (Type 1).F-37Temperature sensor is not working.F-37 E-37Temperature sensor is not working (Type 1).F-40Power control board failure.F-40 E-XXPower control board failure error where XX describes one of 13 possible causes…F-42Power supply issue detected.F-42 E-00Power supply error (Type 2).F-43 E-00Power supply error (Type 2).F-47Power supply from power control board to User Interface is missing, or WIDE…F-47 E-35Power supply from power control board to User Interface is missing, or WIDE…F-47 E-39Power supply from power control board to User Interface is missing, or WIDE…F-47 E-47Power supply from power control board to User Interface is missing, or WIDE…F-56Wrong or invalid configuration (User Interface).F-56 E-00Wrong or invalid configurationF-58Wrong or invalid configuration (power control board).F-58 E-58Wrong or invalid configuration (Type 2).F-60User Interface does not work.F-61Power control board does not work.F-81 E-00Over temperatureF-82 E-00Over temperatureF1 E0EEPROM communication error on the MRC2 oven control.
View all 60 error codes

Service modes (28)

  • Auto TestEnter diagnostic mode (CANCEL>CANCEL>START)
  • CONTROL RESETPress CANCEL > CANCEL > START to enter Service Mode
  • Diagnostics Mode (Auto Test)Press CANCEL > CANCEL > START
  • Diagnostics Mode for Cooktop Controls["Ensure that both cooktop (EGO) controls are OFF (idle mode).","Touch OFF>OFF>ON for the selected…
  • DISPLAYPress CANCEL > CANCEL > START to enter Service Mode
  • EGO Cooktop Control Diagnostics Mode["Ensure both cooktop (EGO) controls are OFF (idle mode)","Touch OFF > OFF > ON for the selected…
  • ENG MODEPress CANCEL > CANCEL > START to enter Service Mode
  • ENG MODE (Engineering Mode)Enter diagnostic mode (CANCEL>CANCEL>START), scroll to 'ENG MODE' (step 2)
  • FAULTSPress CANCEL > CANCEL > START to enter Service Mode
  • MRC Control Module Diagnostic ModePress CANCEL > CANCEL > START
  • MRC2 Diagnostics Mode (Auto Test)["Press CANCEL","Press CANCEL","Press START","Display shows 'TEST ON' with cavity temperature and…
  • MRC2 Service Mode - AUTO TEST["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'AUTO TEST'"]
  • MRC2 Service Mode - CONTROL RESET["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'CONTROL RESET'"]
  • MRC2 Service Mode - DISPLAY["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'DISPLAY'"]
  • MRC2 Service Mode - ENG MODE["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'ENG MODE'","Press START to…
  • MRC2 Service Mode - EXTERNAL FAULTS["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'EXTERNAL FAULTS'"]
  • MRC2 Service Mode - FAULTS["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'FAULTS'"]
  • MRC2 Service Mode - RELAY USAGE["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'RELAY USAGE'"]
  • MRC2 Service Mode - TEST MODE (Relay Checks)["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'TEST MODE'","Press designated…
  • MRC2 Service Mode - TEST ON (Relay Checks)["Press CANCEL","Press CANCEL","Press START","TEST ON is displayed upon entry","Press designated…
  • MRC2 Service Mode - USAGE["Press CANCEL > CANCEL > START to enter Service Mode","Scroll using up arrow/+ or 3 key to…
  • MRC2 Service Mode - VERSION["Press CANCEL > CANCEL > START to enter Service Mode","Scroll to 'VERSION'"]
  • Temperature AdjustmentPress OVEN LIGHT for 5 seconds
  • TEST MODEPress CANCEL > CANCEL > START to enter Service Mode
  • TEST ON (Relay Checks)Press CANCEL > CANCEL > START
  • TEST ON (Relay Control)Enter diagnostic mode (CANCEL>CANCEL>START)
  • USAGEPress CANCEL > CANCEL > START to enter Service Mode
  • VERSIONPress CANCEL > CANCEL > START to enter Service Mode

Full entry steps, exit procedures, and test sequences are available in Max.