Error code reference
Electrolux Cooktop Error Code E77
Heat sink temperature sensor break in the 3 cook zones induction module for the center cooking zone.
Heat sink temperature sensor break in the 3 cook zones induction module for the center cooking zone.
First step from the service manual
1
Replace generator circuit board for the center cook zone in the 3 zones induction module.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
MyPros+ Max
Get the full diagnostic procedure for E77.
- ✓Step-by-step tests with expected resistance, voltage, and continuity values
- ✓Wiring diagram references and connector pinouts from the OEM service manual
- ✓Verified part numbers when replacement is required
Get the full procedure→
$29/month · Cancel anytime · Or $9.95 3-day pass
M+
M+ Max·Electrolux Cooktop
E77 on my Electrolux Cooktop
M+
Heat sink temperature sensor break in the 3
From Service Manual 518211, p.23:
1.Replace generator circuit board for the center cook zone in the 3 zones induction module.
2.Disconnect the sensor and measure resistance at the sensor body. Expected: 10 kΩ to 12 kΩ at 77°F (25°C).
3.Check the sensor harness for opens and shorts. Back-probe the sensor pins at the control board connector; a reading outside 5 kΩ to 50 kΩ indicates a failed sensor.
Part 5304513033
Thermistor
Related Electrolux cooktop codes
All Electrolux cooktop codes →- 10Center zone control defective or key sensor defective.
- 11Center zone control defective or On/Off key sensor…
- 12Center zone control or On/Off key sensor defective.
- 14RR zone control defective or key sensor defective.
- 15RR zone control defective or On/Off key sensor defective.
- 16RR zone control or On/Off key sensor defective.
- 17RF zone control defective or key sensor defective.
- 18RF zone control defective or On/Off key sensor defective.
View all 134 Electrolux cooktop codes
- 19RF zone control or On/Off key sensor defective.
- 2LF zone control defective or key sensor defective.
- 21Timer or key sensor defective.
- 22Timer or On/Off key sensor defective.
- 23Keep Warm key sensor defective or On/Off key sensor…
- 24Lock key sensor defective or On/Off key sensor defective.
- 25Main POWER On/Off key sensor defective.
- 3LF zone control defective or On/Off key sensor defective.
- 30Improper power supply (high voltage) or jumper connections.
- 31Power level failure.
- 32Low voltage output from 12V supply on filter board.
- 33Improper voltage output from 5V filter board.
- 34Communication failure between filter board and power boards.
- 35Improper power supply (low voltage) or jumper connections.
- 36Communication error between main touch control and filter…
- 39Touch control board software configuration does not match…
- 4LF zone control or On/Off key sensor defective.
- 40Communication failure between main touch control and filter…
- 51Element temperature sensor break (LF).
- 52Element temperature sensor break (LR).
- 53Element temperature sensor break (Center).
- 54Element temperature sensor break (RR).
- 55Element temperature sensor break (RF).
- 6LR zone control defective or key sensor defective.
- 7LR zone control defective or On/Off key sensor defective.
- 8LR zone control or On/Off key sensor defective.
- EGeneral error code displayed on element screens (E) while…
- E00Error code displayed as E on cooking zone displays and 00…
- E011Jammed key detected on the touch panel.
- E014Touch Panel Tail missing.
- E015ESEC self test failure.
- E021LIN (Local Interconnect Network) error, no communications…
- E03Error code displayed as E on cooking zone displays and 03…
- E030AC input voltage too high, Induction Housing Assembly (left…
- E031Internal generator error, sync, Induction Housing Assembly…
- E032Power supply defect, Induction Housing Assembly / Left side…
- E033Power supply defect, Induction Housing Assembly / Left side…
- E034Internal generator error, communication, Induction Housing…
- E035AC input voltage too low, Induction Housing Assembly (left…
- E036Communication error, Induction Housing Assembly / Left side…
- E037Heat sink temperature sensor break, Induction Housing…
- E039Configuration mismatch between the ESEC-UIB and the…
- E04Error code displayed as E on cooking zone displays and 04…
- E05Error code displayed as E on cooking zone displays and 05…
- E051Inductor temperature sensor break (Left Front).
- E052Inductor temperature sensor break (Left Rear).
- E054Inductor temperature sensor break (Right Rear).
- E055Inductor temperature sensor break (Right Front).
- E06Error code displayed as E on cooking zone displays and 06…
- E061Left Front inductor temperature sensor too hot.
- E062Left Rear inductor temperature sensor too hot.
- E064Right Rear inductor temperature sensor too hot.
- E065Right Front inductor temperature sensor too hot.
- E07Error code displayed as E on cooking zone displays and 07…
- E070AC input voltage too high, Induction Housing Assembly…
- E071Internal generator error, sync, Induction Housing Assembly…
- E072Power supply defect, Induction Housing Assembly / Right…
- E073Power supply defect, Induction Housing Assembly / Right…
- E074Internal generator error, communication, Induction Housing…
- E075AC input voltage too low, Induction Housing Assembly (right…
- E076Communication error, Induction Housing Assembly / Right…
- E077Heat sink temperature sensor break, Induction Housing…
- E10Center zone control defective key sensor.
- E11Center zone control defective key sensor.
- E12Center zone control key sensor defective.
- E14Right Rear zone control defective key sensor.
- E15Right Rear zone control defective key sensor.
- E16Right Rear zone control key sensor defective.
- E17Right Front zone control key sensor defective.
- E18Right Front zone control key sensor defective.
- E19Right Front zone control key sensor defective.
- E2Left Front zone control defective key sensor.
- E21Timer key sensor defective.
- E22Timer key sensor defective.
- E23Keep warm key sensor defective.
- E24Lock key sensor defective.
- E25Main power key sensor defective.
- E3Left Front zone control defective key sensor.
- E30AC input voltage too high at the 3 cook zones induction…
- E31Internal generator error, sync in the 3 cook zones…
- E32Low voltage output from 12V supply on filter board in the 3…
- E33Improper voltage output from filter board in the 3 cook…
- E34Communication failure between filter board and power boards…
- E35AC input voltage too low in the 3 cook zones induction…
- E36Communication error between main touch control and filter…
- E37Heat sink temperature sensor break (3 zones induction…
- E39Configuration mismatch between the User Interface and the…
- E4Left Front zone control key sensor defective.
- E40Communication failure between main touch control and filter…
- E45Incoming power supply low voltage.
- E51Left Front element temperature sensor break.
- E52Left Rear element temperature sensor break.
- E53Center element temperature sensor break.
- E54Right Rear element temperature sensor break.
- E55Right Front element temperature sensor break.
- E6Left Rear zone control defective key sensor.
- E60Touch control general hardware error, keys.
- E61Left Front element temperature sensor too hot.
- E62Left Rear element temperature sensor too hot.
- E63Center element temperature sensor too hot.
- E64Right Rear element temperature sensor too hot.
- E65Right Front element temperature sensor too hot.
- E7Left Rear zone control defective key sensor.
- E70AC input voltage too high at the 3 cook zones induction…
- E71Internal generator error, sync (center cooking zone).
- E72Low voltage output from 12V supply on filter board in the 3…
- E73Improper voltage output from filter board in the 3 cook…
- E74Internal generator error, communication (3 zones induction…
- E75AC input voltage too low in the 3 cook zones induction…
- E76Communication error in the 3 cook zones induction module…
- E8Left Rear zone control key sensor defective.
- E80Flash/ROM check fail (EEPROM data).
- E90AC input voltage too high in the 2 cook zones induction…
- E91Internal generator error, sync in the 2 cook zones…
- E9212V on the service section too low in the 2 cook zones…
- E935V overcurrent on the switched 5V on the service section (2…
- E94Internal generator error, communication in the 2 cook zones…
- E95AC input voltage too low in the 2 cook zones induction…
- E96Communication error in the 2 cook zones induction module.
- E97Heat sink temperature sensor break in the 2 cook zones…
- FInduction element utensil detection error
- FXXGeneral error code indicated when element displays show 'F'…
- HResidual heat indicator displayed on cooking zone screen…
- HEHot Element indicator displayed and flashing on ESEC screen…
- PFPower Failure indicator displayed on ESEC screen when the…
- SFSabbath mode power failure recovery indicator
78,000+ service manuals · 160,000+ error codes · 55+ brands