Model reference

Electrolux E36IC75FSS

Cooktop

2 documents65 error codes1 service mode

Available documentation

Service Manual

  • IconInductionCooktopServiceManual31643922237 pg
    Covers this model
  • ICON™ Designer Series 36" Induction Drop-In Cooktop SERVICE MANUAL37 pg
    Covers this model
MyPros+ Max

Diagnose your Electrolux E36IC75FSS.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (65)

CodeMeaning
E02Left Front zone control defective key sensor.E03Left Front zone control defective key sensor.E04Left Front zone control key sensor defective.E06Left Rear zone control defective key sensor.E07Left Rear zone control defective key sensor.E08Left Rear zone control key sensor defective.E10Center zone control defective key sensor.E11Center zone control defective key sensor.E12Center zone control key sensor defective.E14Right Rear zone control defective key sensor.E15Right Rear zone control defective key sensor.E16Right Rear zone control key sensor defective.E17Right Front zone control key sensor defective.E18Right Front zone control key sensor defective.E19Right Front zone control key sensor defective.E2Left Front zone control defective key sensor.E21Timer key sensor defective.E22Timer key sensor defective.E23Keep warm key sensor defective.E24Lock key sensor defective.E25Main power key sensor defective.E3Left Front zone control defective key sensor.E30AC input voltage too high at the 3 cook zones induction module.E31Internal generator error, sync in the 3 cook zones induction module / left side…E32Low voltage output from 12V supply on filter board in the 3 cook zone induction…E33Improper voltage output from filter board in the 3 cook zone induction module.E34Communication failure between filter board and power boards in the 3 cook zones…E35AC input voltage too low in the 3 cook zones induction module.E36Communication error between main touch control and filter board (3 cook zones…E37Heat sink temperature sensor break (3 zones induction module / left side…
View all 65 error codes
E39Configuration mismatch between the User Interface and the induction module…E4Left Front zone control key sensor defective.E40Communication failure between main touch control and filter board.E45Incoming power supply low voltage.E51Left Front element temperature sensor break.E52Left Rear element temperature sensor break.E53Center element temperature sensor break.E54Right Rear element temperature sensor break.E55Right Front element temperature sensor break.E6Left Rear zone control defective key sensor.E60Touch control general hardware error, keys.E61Left Front element temperature sensor too hot.E62Left Rear element temperature sensor too hot.E63Center element temperature sensor too hot.E64Right Rear element temperature sensor too hot.E65Right Front element temperature sensor too hot.E7Left Rear zone control defective key sensor.E70AC input voltage too high at the 3 cook zones induction module (same as E30).E71Internal generator error, sync (center cooking zone).E72Low voltage output from 12V supply on filter board in the 3 cook zone induction…E73Improper voltage output from filter board in the 3 cook zone induction module…E74Internal generator error, communication (3 zones induction module).E75AC input voltage too low in the 3 cook zones induction module (same as E35).E76Communication error in the 3 cook zones induction module for the center cooking…E77Heat sink temperature sensor break in the 3 cook zones induction module for the…E8Left Rear zone control key sensor defective.E80Flash/ROM check fail (EEPROM data).E90AC input voltage too high in the 2 cook zones induction module.E91Internal generator error, sync in the 2 cook zones induction module.E9212V on the service section too low in the 2 cook zones induction module.E935V overcurrent on the switched 5V on the service section (2 zones induction…E94Internal generator error, communication in the 2 cook zones induction module.E95AC input voltage too low in the 2 cook zones induction module.E96Communication error in the 2 cook zones induction module.E97Heat sink temperature sensor break in the 2 cook zones induction module.

Service modes (1)

  • Configuration reset (E39 resolution)Press and hold WARM key, then press Right Front zone ON key until beep (keep holding WARM), release…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax