What the Ed error code actually means

Your LG washer detected that the water coming in at the start of a Delicate or Wool cycle was too hot, which could damage sensitive fabrics, so it stopped and drained the water to protect your clothes. This can also happen if a sensor inside the machine is malfunctioning and sending a faulty signal. The machine is working as designed by refusing to wash delicates in scalding water.

Diagnostic procedure

The full Ed procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Clear by POWER S/W OFF.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Ed procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Ed

Ranked by how often they cause this code
  1. 1Reversed hot and cold water inlet hoses
  2. 2Hot water supply temperature too high at cold inlet
  3. 3Faulty water inlet valve
  4. 4Defective thermistor or temperature sensor
  5. 5Abnormal water level pressure sensor signal

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Ed

What does Ed mean on a LG washer?
The Ed code on an LG washer signals an abnormal water temperature error that occurs when water entering the drum during a Delicate or Wool cycle is 50 degrees Celsius or higher. It can also trigger when the water level pressure sensor produces an abnormal frequency of 24.5 kHz. In both cases, the washer automatically drains and runs a forced 2-minute drain to protect fabrics and the machine. The cycle will not proceed until the issue is resolved.
Is it safe to keep using my LG washer if it shows the Ed code?
The washer intentionally stops and drains when it displays the Ed code, so it will not complete the cycle on its own. Running Delicate or Wool cycles repeatedly without resolving the cause risks potential fabric damage if the protection system were to fail. It is safe to use other cycles that do not trigger the temperature threshold while you diagnose the issue, but the root cause should be addressed before using heat-sensitive fabric cycles again.
How much does it cost to repair an LG washer with the Ed error?
If the fix is simply reconnecting reversed hoses, there is no parts cost involved. Replacing a faulty water inlet valve typically ranges from $50 to $150 for parts, while a thermistor or pressure sensor replacement can range from $20 to $80 in parts, with labor costs varying by region and service provider. Diagnosis by a qualified technician is recommended if the simple checks do not resolve the issue.
Will turning the washer off clear the Ed error code?
Powering the washer off using the power switch is the first recommended step and can clear the Ed code if the triggering condition was temporary, such as a brief spike in hot water supply temperature. However, if the underlying cause persists, such as reversed hoses, a faulty valve, or a failed sensor, the code will return on the next Delicate or Wool cycle. Clearing the code without addressing the root cause is only a short-term measure.
How do I fix the Ed error on my LG washer?
Start by turning the machine off and checking that the hot and cold water supply hoses are connected to the correct inlets on the back of the washer. If the hoses are correct, check whether your household hot water supply is crossing into the cold line. If plumbing connections look fine, a technician should test the thermistor resistance and inspect the water level pressure sensor and its hose for clogs, damage, or wiring faults producing the abnormal 24.5 kHz frequency.