mypros+
Error code reference

Samsung Heat Pump Error Code E206

Compressor down by discharge temperature sensor

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E206 error code actually means

Your Samsung heat pump has shut down the compressor because a sensor detected that the compressor was running dangerously hot, above 135°C at its outlet. This is a protective shutdown to prevent serious internal damage to the unit. The problem could be a faulty temperature sensor, low refrigerant, or a closed valve, and a technician will need diagnostic tools to determine which.

Diagnostic procedure

The full E206 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check compressor emission sensor resistance; connect S-net and manifold gauge; check service valve.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E206 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E206

Ranked by how often they cause this code
  1. 1Low refrigerant charge
  2. 2Faulty compressor emission temperature sensor
  3. 3Closed or restricted service valve
  4. 4Refrigerant restriction or blockage
  5. 5Compressor internal fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E206

What does E206 mean on a Samsung heat pump?
E206 means the compressor has been shut down because the discharge temperature sensor detected a temperature exceeding 135°C at the compressor outlet. This is a protective fault designed to prevent mechanical damage to the compressor. The cause could be a refrigerant system issue such as low charge or a closed service valve, or it could be a failed temperature sensor reporting an incorrect value. A technician with manifold gauges and an S-net diagnostic tool is needed to confirm the root cause.
Is it safe to keep running my heat pump with an E206 error?
No. The E206 error triggers a compressor shutdown specifically to protect the unit from damage caused by overheating. Attempting to bypass or repeatedly reset the system without resolving the underlying cause risks serious damage to the compressor, which is one of the most expensive components in the system. The heat pump should remain off until the fault is properly diagnosed and repaired.
How much does it cost to repair a Samsung heat pump E206 error?
Repair costs vary depending on the root cause. If the fault is a closed service valve or a minor refrigerant adjustment, costs may be relatively low, typically in the range of $100 to $300 for a service call and labor. A failed discharge temperature sensor replacement could run $150 to $400 including parts and labor. If the compressor itself is damaged due to sustained overheating, replacement costs can range from $1,000 to $2,500 or more depending on the unit capacity and installation complexity.
Can I fix E206 on my Samsung heat pump myself?
Diagnosing and repairing E206 requires specialized tools including manifold gauges and the Samsung S-net diagnostic system, along with EPA certification if refrigerant handling is involved. Homeowners can check that the service valves on the outdoor unit are fully open, but beyond that, this repair should be handled by a qualified HVAC technician. Attempting to add refrigerant or replace components without proper diagnosis may not resolve the fault and could cause additional damage.
Will resetting my Samsung heat pump clear the E206 error?
A power reset may temporarily clear the fault and allow the unit to restart, but the error will return if the underlying cause is not corrected. If the discharge temperature exceeds 135°C again during operation, the control board will shut the compressor down and display E206 again. Resetting without diagnosis is not a repair and may delay proper service while risking compressor damage.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass