Model reference
Samsung RMAH160GAM0SER
Air Conditioner
3 documents164 error codes3 service modes
Available documentation
Service Manual
- LG Samsung RMAH160GAM0SER Disassembly & Reassembly78 pg
Wiring Diagram
- LG Samsung RMAH160GAM0SER Wiring Diagram20 pg
Other
- LG Samsung RMAH160GAM0SER Installation25 pg
MyPros+ Max
Diagnose your Samsung RMAH160GAM0SER.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (164)
CodeMeaning
AxIndoor unit EVAP IN sensor breakaway for xth indoor unit.BxOPEN/SHORT error of EVAP OUT sensor in xth indoor unit.ChCompressor preheating indicatorCxOPEN/SHORT error of room sensor in xth indoor unit.DxOPEN/SHORT error of EVAP IN sensor in xth indoor unit.E1System down due to communication error after completion of trackingE101Communication error between the indoor unit and the panel (PAC).E102Indoor unit room temperature sensor open/short error.E103Indoor unit EVAP IN sensor open/short error.E104Indoor unit EVAP OUT sensor open/short error.E105Indoor unit EVAP IN sensor breakaway.E106Indoor unit EVAP OUT sensor breakaway.E107Simultaneous breakaway of Indoor unit EVAP IN/OUT sensor.E108Auxiliary (electric) heater sensor 1 error.E109Auxiliary (electric) heater sensor 2 error.E110Auxiliary (electric) heater sensor 3 error.E111Shutter sensor error.E112Perfect fan sensor error (PAC).E113MCU temperature sensor open/short error.E121Indoor unit EEV open failure.E122Indoor unit EEV close failure.E153Indoor unit float switch detection.E154Indoor fan error.E155Mixed operation errorE156EEPROM error.E157Option setting error.E158Electric heater discharge temperature protect error.E159No fan error related to the electric heater.E160Software setup error in peripheral control device using option.E161The 1st MCU SOL V/V cooling/heating opening at the same time.View all 164 error codes
E162The 2nd MCU SOL V/V cooling/heating opening at the same time.E163The 2nd MCU SOL V/V error.E164No change of EVAP IN temperature during piping check.E165No change of EVAP OUT temperature during piping check.E166Change of EVAP IN temperature of other indoor unit during piping check.E167Change of EVAP OUT temperature of other indoor unit during piping check.E2Tracking errorE201Installed indoor unit number setting error on outdoor unit.E202Communication error between indoor and outdoor unit.E203Outdoor PCB MICOM communication error between main and sub.E204Communication error between the outdoor unit and MCU.E205Indoor unit connected with confluence kit without continuity.E206Indoor unit connected with confluence kit and setting address was overlapped…E207MCU address does not match with indoor unit address.E208Installed MCU quantity set-up error in the outdoor PCB.E209MCU address setting was overlapped.E210Rotary switch for indoor unit address in MCU was overlapped among MCUs.E211DIP switch for indoor unit setting was ON position even though indoor unit was…E212DIP switch for indoor unit setting was OFF position even though indoor unit was…E262Digital discharge sensor breakawayE263Fixed 1 discharge sensor breakawayE264Fixed 2 discharge sensor breakaway.E265Fixed 3 discharge sensor breakaway.E266Sump-main breakaway error.E267Sump Sub 1 breakaway error.E268Sump Sub 2 breakaway error.E269Sump Sub 3 breakaway error.E270Suction breakaway error.E271SUMP TEMP DIGITAL sensor error OPEN/SHORTE272SUMP TEMP FIXED 1 sensor error OPEN/SHORTE273SUMP TEMP FIXED 2 sensor error OPEN/SHORTE274SUMP TEMP FIXED 3 sensor error OPEN/SHORTE275High pressure sensor error OPEN/SHORTE276Low pressure sensor error OPEN/SHORTE277High pressure sensor breakaway.E278Low pressure sensor breakaway.E279Suction temperature sensor error OPEN/SHORT.E280Main cooling solenoid valve open error.E2814-Way valve operation error.E3Indoor unit float switch errorE301Outdoor temperature sensor open/short error.E302Outdoor temperature sensor breakaway.E303COND-OUT MAIN temperature sensor error OPEN/SHORT.E304COND-OUT SUB 1 temperature sensor error OPEN/SHORT.E305COND-MID sensor breakaway of outdoor unit.E306COND-OUT 1 breakaway.E307PWM discharge temperature sensor error OPEN/SHORTE308Fixed capacity compressor 1 discharge sensor error OPEN/SHORTE309Fixed capacity compressor 2 discharge sensor error OPEN/SHORTE310Fixed capacity compressor 3 discharge sensor error OPEN/SHORTE4Setting error of option switch in indoor unitE401Outdoor unit freezing detection 1.E402Outdoor unit freezing detection 2.E403Outdoor unit freezing detection 3E404Outdoor unit overload 1 protection control error.E405Outdoor unit overload 2 protection control error.E406Outdoor unit overload 3 protection control error.E407Compressor down by high pressure sensor protection control 1.E408Compressor down by high pressure sensor protection control 2.E409Compressor down by high pressure sensor protection control 3.E410Compressor down by low pressure sensor protection control 1.E411Compressor down by low pressure sensor protection control 2.E412Compressor down by low pressure sensor protection control 3.E413Outdoor unit SUMP DOWN 1 protection control.E414Outdoor unit SUMP DOWN 2 protection control.E415Outdoor unit SUMP DOWN 3 protection control.E416Outdoor unit discharge temperature 1 protection control.E417Outdoor unit discharge temperature 2 protection control.E418Outdoor unit discharge temperature 3 protection control.E419Outdoor unit EEV open 1 self-diagnosis error.E420Outdoor unit EEV open 2 self-diagnosis error.E421Outdoor unit EEV open 3 self-diagnosis error.E422Outdoor unit EEV close 1 self-diagnosis error.E423Outdoor unit EEV close 2 self-diagnosis error.E424Outdoor unit EEV close 3 self-diagnosis error.E425Outdoor unit reverse phase detection 1 error.E426Outdoor unit reverse phase detection 2 error.E427Outdoor unit reverse phase detection 3 error.E428Outdoor unit compression rate 1 errorE429Outdoor unit compression rate 2 error.E430Outdoor unit compression rate 3 error.E431Forbid heating mode operation when outdoor temperature over 30°C.E432Forbid cooling mode operation when outdoor temperature below -5°C.E433Refrigerant charging operation restriction at 15°C or above outdoor temperature…E434Instant power offE440Low pressure detection error at initial compressor startE5Indoor unit sensor or operation related error (specification 1 grouping for…E501Defrosting operation.E502Low discharge pressureE503Equability (oil leveling) operation.E504Loading failure.E505Full leakage of refrigerant of outdoor unit.E601Communication error between wired remote controller and indoor unit.E602Communication error between master wired remote controller and slave wired…E603Communication error between 7 day scheduler and wired remote controller.FxElectronic expansion valve open error for xth indoor unit.G2Total leakage of refrigerant in outdoor unit / Loading failure.G3Breakaway of COND MID sensor in outdoor unit.G4Breakaway of OIL temperature sensor (detected once or more times).G5Breakaway of SUCTION sensor.G6Breakaway of fixed compressor discharge sensor (detected once or more times).G7Outdoor unit error (per specification 1 priority listing).G8Outdoor unit error (per specification 1 priority listing).G9Outdoor unit error (per specification 1 priority listing).P0System down due to high temperature of discharge sensorP1System down due to high temperature of COND sensorP2SUMP COMP DOWNP3System down due to low pressure switch detectionP4Reverse phase or open phase errorP5System down due to frozen heat exchangerP6In removing frostP7Error of momentary power failureP701Float switch detection error (low level riskP702Indoor unit EEV closing error (low level risk).P703Indoor unit EEV opening error (low level risk).P704MCU solenoid valve failure (low level risk).P8Compressor down due to protection control of high pressure sensorP9Compressor down due to protection control of low pressure sensorPACompressor down due to protection control of condensation ratioqxElectronic expansion valve close error for xth indoor unit.rxIndoor unit EVAP OUT sensor breakaway for xth indoor unit.sxSimultaneous breakaway of indoor unit EVAP IN and EVAP OUT sensors for xth…t1Error of outdoor temperature sensor (OPEN/SHORT)t2Error of COND temperature sensor (OPEN/SHORT)t3Error of PWM discharge temperature sensor (OPEN/SHORT)t4Error of liquid refrigerant pipe (COND OUT) temperature sensor (OPEN/SHORT)t5Error of OIL temperature sensor (OPEN/SHORT)t6Error of SUCTION temperature sensor (OPEN/SHORT)t7Error of high pressure sensor (OPEN/SHORT)t8Error of low pressure sensor (OPEN/SHORT)t9Error of fixed compressor discharge sensor (OPEN/SHORT)toOutdoor unit sensor related error (per specification 1 priority listing).tuOutdoor unit sensor related error (per specification 1 priority listing).vxIndoor unit fan motor starting error for xth indoor unit.
Service modes (3)
- Error resetPress KEY 3 (K3) reset key on outdoor unit PCB.
- Piping check displayPress KEY 5 (K5) after pipe check to display error information.
- Test operationPress KEY 4 (K4) on outdoor unit PCB to enter test operation mode (all indoor units operate).
Full entry steps, exit procedures, and test sequences are available in Max.