Model reference

Samsung RMAH180GAM0SER

Air Conditioner

4 documents75 error codes3 service modes

Available documentation

Service Manual

  • LG Samsung RMAH180GAM0SER Disassembly & Reassembly78 pg
    Covers this model

Wiring Diagram

  • LG Samsung RMAH180GAM0SER Wiring Diagram20 pg
    Covers this model
  • Schematic Diagram14 pg
    Covers this model

Other

  • LG Samsung RMAH180GAM0SER Operation Instruction _ Installation25 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung RMAH180GAM0SER.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (75)

View all 75 error codes
E4Mismatching of set indoor unit numbers with communicated indoor unit numbers…E425Outdoor unit reverse phase detection error for 3-phase power.E5Setting error of option switch in indoor unit (wired remote controller address…E601Communication error between wired remote controller and indoor unit.E602Communication error between master wired remote controller and slave wired…E603Communication error between 7 day scheduler and wired remote controller.FxElectronic expansion valve open error for indoor unit x.G2Total leakage of refrigerant in outdoor unit or loading failure.G3Breakaway of COND MID sensor in outdoor unit.G4Breakaway of OIL temperature sensor (detected once or more times during first…G5Breakaway of SUCTION sensor (detected during first 30 minutes of compressor…G6Breakaway of fixed compressor discharge sensor (detected once or more times).G7High pressure sensor breakaway.G8Low pressure sensor breakaway.G9Suction temperature sensor error (OPEN/SHORT).P0System down due to high temperature of discharge sensor (discharge temperature…P1System down due to high temperature of COND sensor (condensate temperature of…P2SUMP COMP DOWNP3System down due to low pressure switch detection (low pressure lower than 1.2…P4Reverse phase or open phase error on 3-phase power supply to outdoor unit.P5System down due to frozen heat exchanger (indoor unit heat exchanger…P6Error of momentary power failureP7Compressor down due to protection control of high pressure sensor (high…P701Outdoor unit freezing detection 1.P702Indoor unit EEV closing error.P703Indoor unit EEV opening error.P704MCU Sol v/v failure.P8Compressor down due to protection control of low pressure sensor (low pressure…P9In removing frostPACompressor down due to protection control of condensation ratio (compression…qxElectronic expansion valve close error for indoor unit x.rxIndoor unit EVAP OUT sensor breakaway for unit x.sxSimultaneous breakaway of indoor unit EVAP IN and EVAP OUT sensor for unit x.t1Error of outdoor temperature sensor (OPEN/SHORT). Error levelt2Error of COND TEMP sensor (OPEN/SHORT). Error levelt3Error of PWM Discharge TEMP sensor (OPEN/SHORT). Detected when outdoor…t4Error of liquid refrigerant pipe (COND OUT) TEMP sensor (OPEN/SHORT). Error…t5Error of OIL TEMP sensor (OPEN/SHORT). Detected when outdoor temperature is…t6Error of SUCTION TEMP sensor (OPEN/SHORT). Error levelt7Error of high pressure sensor (OPEN/SHORT)t8Error of low pressure sensor (OPEN/SHORT)t9Error of fixed compressor discharge sensor (OPEN/SHORT). Detected when outdoor…toRestriction of heating operation when outdoor temperature is over 30°C, or…tuRestriction of cooling operation when outdoor temperature is below -5°C.vxError of fan starting for indoor unit x.

Service modes (3)

  • Error resetPress KEY 3 (K3) reset key on outdoor unit PCB.
  • Piping checkPerform piping check procedure, then press KEY 5 (K5) on outdoor unit PCB to display error…
  • Test operationPress KEY 4 (K4) on outdoor unit PCB to enter test operation mode.

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax