What the E403 error code actually means

Your Samsung air conditioner has detected that the refrigerant pressure inside the system is too low to safely start the compressor. This is most often caused by a refrigerant leak, but it can also be a faulty pressure sensor giving a false reading. The unit is protecting itself from damage by refusing to run until the pressure problem is resolved.

Diagnostic procedure

The full E403 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Measure pressure using manifold gauge when system is stopped.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E403 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E403

Ranked by how often they cause this code
  1. 1Low refrigerant charge due to a leak
  2. 2Faulty low pressure sensor
  3. 3Restricted or blocked expansion valve
  4. 4Blocked or saturated filter drier
  5. 5Wiring fault in the sensor circuit

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E403

What does E403 mean on a Samsung air conditioner?
E403 indicates the system has detected suction-side refrigerant pressure below the minimum required threshold before pump down start. Specifically, the low pressure sensor read below 3.1 kg/cm2G during cooling or below 2.6 kg/cm2G during heating for 3 consecutive seconds. The control board blocks the compressor from starting to prevent mechanical damage. The fault points to either a low refrigerant charge or a problem with the pressure sensor itself.
Is it safe to keep running my air conditioner with an E403 error?
No. The E403 fault is a protective lockout that prevents the compressor from starting specifically because running on low refrigerant pressure can cause severe compressor damage. The unit will refuse to operate normally until the fault condition is resolved. Attempting to override the lockout or repeatedly resetting the unit without addressing the root cause risks costly compressor failure.
Will resetting my Samsung air conditioner clear the E403 error?
A power reset may temporarily clear the fault display, but E403 will return immediately if the underlying pressure condition still exists. Because the sensor continuously monitors suction pressure and the fault triggers within 3 seconds of the threshold being breached, the lockout will reactivate as soon as the system attempts to start. A reset is only a valid resolution after the actual cause, whether a refrigerant leak, faulty sensor, or restriction, has been diagnosed and corrected.
Can I fix E403 on my Samsung air conditioner myself?
Some basic checks, such as inspecting wiring to the low pressure sensor and verifying the sensor connector is secure, can be done without special tools. However, diagnosing and correcting low refrigerant pressure requires a manifold gauge set and EPA certification to handle refrigerants legally. If the system has lost refrigerant due to a leak, a certified HVAC technician must locate the leak, repair it, and recharge the system.
How much does it cost to repair an E403 error on a Samsung air conditioner?
Repair costs vary widely depending on the root cause. A sensor replacement typically runs in the range of $100 to $250 including labor. If the system needs a leak repair and refrigerant recharge, costs commonly range from $200 to $600 or more depending on the leak location, refrigerant type, and quantity required. A blocked expansion valve or filter drier replacement will generally fall in the $150 to $400 range for parts and labor.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass