Samsung Air Conditioner Error Code P505
Outdoor unit overload 2 protection control error.
Outdoor unit overload 2 protection control error.
Get the full diagnostic procedure for P505.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What P505 means on a Samsung air conditioner
The P505 error code on a Samsung air conditioner indicates an outdoor unit overload 2 protection control error. This fault is related to the compressor or motor protection circuitry in the outdoor unit detecting an overcurrent or overload condition on a secondary monitored channel. The system's protection logic triggers this code when current draw or thermal stress on a key outdoor component exceeds safe operating thresholds, causing the unit to shut down to prevent permanent damage.
Overload protection circuits in outdoor units continuously monitor the electrical load on the compressor and associated motors. When a component draws more amperage than the rated limit, or when thermal sensors detect heat buildup beyond safe levels, the control board logs this fault and halts operation. The "overload 2" designation suggests this is tied to a specific secondary protection loop, which may monitor a fan motor, a secondary compressor winding, or an additional current sensing circuit separate from the primary overload protection path.
Common contributors to this fault include refrigerant charge issues, restricted airflow across the condenser coil, a failing compressor drawing high current, or a defective overload relay or protection component on the control board. Electrical supply problems such as low voltage or phase imbalance in multi-phase systems can also force components to draw excess current. A thorough diagnosis should include measuring supply voltage, checking amperage draw on outdoor unit components, inspecting the condenser coil for blockage, and verifying refrigerant pressure levels before replacing any parts.
Source: manufacturer service documentation.
Common causes of P505
- 01
Compressor drawing excessive current
Part replacementA worn or failing compressor may draw amperage beyond its rated limit, triggering the overload protection circuit. This can be identified by measuring the compressor's running amperage with a clamp meter and comparing it to the unit's nameplate rating.
- 02
Restricted condenser coil airflow
Wiring / connectionA dirty or blocked condenser coil forces the compressor to work harder, increasing current draw and heat buildup. Inspect the outdoor coil for debris, dirt, or damage and clean it thoroughly before proceeding with further diagnostics.
- 03
Incorrect refrigerant charge
Wiring / connectionAn overcharged or undercharged refrigerant system creates abnormal operating pressures that increase the load on the compressor. This requires checking system pressures with a manifold gauge set and correcting the charge as needed.
- 04
Low or unstable supply voltage
Wiring / connectionInsufficient supply voltage causes motors and the compressor to draw higher current to maintain output, potentially tripping overload protection. Measure the incoming voltage at the outdoor disconnect under load conditions to rule this out.
- 05
Faulty overload relay or protection component
Part replacementThe overload relay or the current sensing component on the outdoor control board may be defective and triggering a false protection trip even when current levels are normal. This is typically identified after ruling out all other causes and testing or replacing the suspect component.
Frequently asked questions about P505
What does P505 mean on a Samsung air conditioner?
Can I fix a P505 error myself?
Is a P505 error dangerous to ignore?
How much does it cost to repair a P505 error on a Samsung air conditioner?
Will resetting the air conditioner clear the P505 error?