Samsung Air Conditioner Error Code P505

Outdoor unit overload 2 protection control error.

Outdoor unit overload 2 protection control error.

MyPros+ Max

Get the full diagnostic procedure for P505.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What P505 means on a Samsung air conditioner

The P505 error code on a Samsung air conditioner indicates an outdoor unit overload 2 protection control error. This fault is related to the compressor or motor protection circuitry in the outdoor unit detecting an overcurrent or overload condition on a secondary monitored channel. The system's protection logic triggers this code when current draw or thermal stress on a key outdoor component exceeds safe operating thresholds, causing the unit to shut down to prevent permanent damage.

Overload protection circuits in outdoor units continuously monitor the electrical load on the compressor and associated motors. When a component draws more amperage than the rated limit, or when thermal sensors detect heat buildup beyond safe levels, the control board logs this fault and halts operation. The "overload 2" designation suggests this is tied to a specific secondary protection loop, which may monitor a fan motor, a secondary compressor winding, or an additional current sensing circuit separate from the primary overload protection path.

Common contributors to this fault include refrigerant charge issues, restricted airflow across the condenser coil, a failing compressor drawing high current, or a defective overload relay or protection component on the control board. Electrical supply problems such as low voltage or phase imbalance in multi-phase systems can also force components to draw excess current. A thorough diagnosis should include measuring supply voltage, checking amperage draw on outdoor unit components, inspecting the condenser coil for blockage, and verifying refrigerant pressure levels before replacing any parts.

Source: manufacturer service documentation.

Common causes of P505

  1. 01

    Compressor drawing excessive current

    Part replacement

    A worn or failing compressor may draw amperage beyond its rated limit, triggering the overload protection circuit. This can be identified by measuring the compressor's running amperage with a clamp meter and comparing it to the unit's nameplate rating.

  2. 02

    Restricted condenser coil airflow

    Wiring / connection

    A dirty or blocked condenser coil forces the compressor to work harder, increasing current draw and heat buildup. Inspect the outdoor coil for debris, dirt, or damage and clean it thoroughly before proceeding with further diagnostics.

  3. 03

    Incorrect refrigerant charge

    Wiring / connection

    An overcharged or undercharged refrigerant system creates abnormal operating pressures that increase the load on the compressor. This requires checking system pressures with a manifold gauge set and correcting the charge as needed.

  4. 04

    Low or unstable supply voltage

    Wiring / connection

    Insufficient supply voltage causes motors and the compressor to draw higher current to maintain output, potentially tripping overload protection. Measure the incoming voltage at the outdoor disconnect under load conditions to rule this out.

  5. 05

    Faulty overload relay or protection component

    Part replacement

    The overload relay or the current sensing component on the outdoor control board may be defective and triggering a false protection trip even when current levels are normal. This is typically identified after ruling out all other causes and testing or replacing the suspect component.

See the test procedure for each cause

Frequently asked questions about P505

What does P505 mean on a Samsung air conditioner?
P505 indicates an outdoor unit overload 2 protection control error. This means the system's protection circuitry has detected an overload condition on a secondary monitored component in the outdoor unit, such as the compressor or a motor. The unit shuts down automatically to prevent damage. A technician will need to diagnose the root cause before the system can be safely restarted.
Can I fix a P505 error myself?
Some basic checks are safe to perform yourself, such as clearing debris from around the outdoor unit and cleaning a visibly dirty condenser coil. However, diagnosing the underlying cause requires measuring voltage, amperage, and refrigerant pressures, which involves specialized tools and working with electrical components that carry serious shock risk. It is strongly recommended to have a qualified HVAC technician perform the full diagnosis and repair.
Is a P505 error dangerous to ignore?
Yes, ignoring this error can lead to serious consequences. The overload protection is designed to prevent component damage, and running the system in a fault condition can cause the compressor to fail prematurely or create an electrical hazard. Keep the unit off until the fault is properly diagnosed and resolved.
How much does it cost to repair a P505 error on a Samsung air conditioner?
Repair costs depend entirely on the root cause. Cleaning the condenser coil or correcting refrigerant charge may cost in the range of $100 to $300 for a service call. Replacing a faulty overload relay or control board component typically runs $150 to $500. Compressor replacement, if needed, is the most expensive outcome and can range from $600 to $1,500 or more depending on the unit size and parts availability.
Will resetting the air conditioner clear the P505 error?
A reset may temporarily clear the fault code and allow the unit to restart, but if the underlying overload condition still exists, the P505 error will return quickly. Resetting without diagnosing the cause is not a fix and may accelerate damage to the compressor or other outdoor components. Always identify and correct the source of the overload before cycling power.