Samsung Air Conditioner Error Code E396

DC voltage sensor error of Fan2.

DC voltage sensor error of Fan2.

First step from the service manual

Check DC-Link voltage connection wire between Inverter PCB and Fan PCB.

The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.

MyPros+ Max

Get the full diagnostic procedure for E396.

  • Step-by-step tests with expected resistance, voltage, and continuity values
  • Wiring diagram references and connector pinouts from the OEM service manual
  • Verified part numbers when replacement is required
Get the full procedure

$29/month · Cancel anytime · Or $9.95 3-day pass

What E396 means on a Samsung air conditioner

Error code E396 on a Samsung air conditioner indicates a DC voltage sensor error on the second fan motor (Fan2). This code is triggered when the inverter PCB cannot properly read the DC-link voltage associated with the Fan2 circuit. The DC-link voltage is the intermediate DC bus voltage generated after AC power is rectified and filtered, and it serves as the supply rail for driving the fan motor through the inverter stage. When the sensor reading falls outside the expected range or is absent entirely, the system flags E396 and typically halts fan operation to prevent component damage.

The most critical starting point in diagnosing E396 is inspecting the DC-link voltage connection wire that runs between the inverter PCB and the fan PCB. This harness carries both the voltage signal and sometimes the reference ground needed for the sensor circuit to function accurately. A loose connector, a damaged wire, or corrosion at either terminal end can interrupt the signal and produce a false or out-of-range reading. Physical damage from vibration, pinching during installation, or moisture ingress are all common ways this wiring becomes compromised over time.

If the wiring and connectors check out visually and electrically, the fault may lie within the fan PCB itself, specifically in the voltage sensing circuitry, or within the inverter PCB that processes the signal. Component-level failures such as a damaged sensing resistor, failed capacitor on the DC bus, or a defective inverter PCB can all produce this error. A technician should verify actual DC-link voltage at the appropriate test points on the inverter PCB before condemning either board.

Source: manufacturer service documentation.

Common causes of E396

  1. 01

    Loose or disconnected DC-link wiring harness

    Wiring / connection

    The connection wire between the inverter PCB and the fan PCB may have come loose or partially disconnected, interrupting the voltage signal. Inspect both connector ends for secure seating and signs of backing out.

  2. 02

    Damaged or shorted DC-link wire

    Part replacement

    The harness between the inverter PCB and fan PCB may have a broken conductor, pinched insulation, or a short caused by vibration or physical contact with sharp edges. A continuity and insulation resistance check on the wire will reveal this.

  3. 03

    Corrosion or contamination at connector terminals

    Wiring / connection

    Moisture or debris at the connector pins on either the inverter PCB or fan PCB can increase contact resistance and produce an inaccurate or absent voltage sensor reading. Clean terminal pins and inspect for oxidation.

  4. 04

    Faulty fan PCB

    Part replacement

    The fan PCB may have a failed voltage sensing component, preventing it from correctly processing the DC-link voltage signal. This is suspected after wiring and connectors have been confirmed good.

  5. 05

    Faulty inverter PCB

    Part replacement

    If the inverter PCB is not generating or transmitting the correct DC-link voltage, the sensor on the fan PCB will report an error. Verify DC-link voltage at the inverter PCB test points before replacing this board.

See the test procedure for each cause

Frequently asked questions about E396

What does E396 mean on a Samsung air conditioner?
E396 indicates a DC voltage sensor error for the second fan motor (Fan2). The system monitors the DC-link voltage used to drive the fan through the inverter stage, and this code appears when that sensor reading is absent or out of range. The unit protects itself by suspending normal fan operation until the fault is resolved.
Can I fix E396 myself, or do I need a technician?
A knowledgeable DIYer can safely inspect and reseat the DC-link wiring harness between the inverter PCB and the fan PCB, which is the first recommended diagnostic step. However, testing actual DC-link voltage and diagnosing PCB-level faults requires electrical knowledge and appropriate test equipment. If reseating the connector does not resolve the error, a qualified technician should perform further diagnosis.
Is it safe to keep running the air conditioner with an E396 error?
It is not recommended to continue operating the unit with an active E396 error. The system has detected a fault in the fan motor voltage sensing circuit, which means Fan2 may not be operating correctly. Running the unit without proper fan function can cause overheating of internal components and lead to more serious damage.
Will resetting the air conditioner clear the E396 error?
A power reset may temporarily clear the error display, but if the underlying wiring fault or component failure is still present, the code will return once the unit restarts and attempts to monitor the DC-link voltage again. The root cause must be identified and corrected for the error to be permanently resolved.
How much does it cost to repair a Samsung air conditioner showing E396?
Repair costs vary depending on the root cause. If only the wiring harness needs reseating or replacement, costs are typically in the range of $50 to $150 for a service call. If a fan PCB or inverter PCB replacement is required, parts and labor combined can range from $200 to $600 or more depending on the specific model and local labor rates.