Model reference
Samsung RMAH140GAM0SER
Air Conditioner
4 documents95 error codes4 service modes
Available documentation
Service Manual
- LG Samsung RMAH140GAM0SER Disassembly & Reassembly78 pg
- Setup the model option8 pg
Wiring Diagram
- LG Samsung RMAH140GAM0SER Wiring Diagram20 pg
Other
- LG Samsung RMAH140GAM0SER Operation Instruction _ Installation25 pg
MyPros+ Max
Diagnose your Samsung RMAH140GAM0SER.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (95)
CodeMeaning
AxBreakaway of indoor unit EVAP IN sensor for xth indoor unit.BxBreakaway of indoor unit EVAP OUT sensor for xth indoor unit.ChCompressor preheating in progressCxElectronic expansion valve open error for xth indoor unitDxElectronic expansion valve close error for xth indoor unit.E1System down due to communication error after completion of trackingE101Communication error between the indoor unit and the Panel PAC.E121Indoor unit room tempE122Indoor unit EVAP IN sensor open/short errorE153Indoor unit float switch detection error.E154Indoor fan error.E161The 1st MCU SOL V/V cooling/heating opening at the same time.E162EEPROM errorE163Option setting errorE2Tracking errorE201Installed indoor unit number setting error on outdoor PCB.E202Communication error between indoor and outdoor unit.E203Outdoor PCB MICOM communication error between main and sub.E210Communication error between the outdoor unit and MCUE211Indoor unit connected with confluence kit without continuity.E262Discharge temperature sensor breakawayE263Discharge temperature sensor breakawayE264Discharge temperature sensor breakawayE3Indoor unit float switch errorE4Setting error of option switch in indoor unitE401Outdoor unit freezing detection 1E402Outdoor unit freezing detection 2E403Outdoor unit freezing detection 3-freezing COMP DOWNE404Outdoor unit overload 1 protection control errorE405Outdoor unit overload 2 protection control errorView all 95 error codes
E406Outdoor unit overload 3 protection control errorE407Compressor down by high pressure sensor protection control 1E408Compressor down by high pressure sensor protection control 2E409Compressor down by high pressure sensor protection control 3E410Compressor down by low pressure sensor protection control 1E411Compressor down by low pressure sensor protection control 2E412Compressor down by low pressure sensor protection control 3E413Outdoor unit SUMP DOWN 1 protection controlE414Outdoor unit SUMP DOWN 2 protection controlE415Outdoor unit SUMP DOWN 3 protection controlE416Outdoor unit discharge temperature 1 protection controlE417Outdoor unit discharge temperature 2 protection controlE418Outdoor unit discharge temperature 3 protection controlE419Outdoor unit EEV open 1 self diagnosis errorE420Outdoor unit EEV open 2 self diagnosis errorE421Outdoor unit EEV open 3 self diagnosis errorE422Outdoor unit EEV close 1 self diagnosis errorE423Outdoor unit EEV close 2 self diagnosis errorE424Outdoor unit EEV close 3 self diagnosis errorE425Low pressure sensor error OPEN/SHORTE426Outdoor unit reverse phase detection 2 errorE427Outdoor unit reverse phase detection 3 errorE428Outdoor unit compression rate 1 errorE429Outdoor unit compression rate 2 errorE430Outdoor unit compression rate 3 errorE5Mismatching of the set indoor unit numbers with communicated numbers after 5…FxSimultaneous breakaway of indoor unit EVAP IN and EVAP OUT sensor for xth…G2Total leakage of refrigerant in outdoor unit or loading failure.G3Breakaway of COND MID sensor in outdoor unit.G4Breakaway of OIL temperature sensor (detected once or more times)G5Breakaway of SUCTION sensorG6Breakaway of fixed compressor discharge sensor (detected once or more times)G7No cooling operationG8No heating operationG9Self-diagnosis of condensation sensor.P0System down due to high temperature of discharge sensorP1System down due to high temperature of COND sensorP2SUMP COMP DOWNP3System down due to low pressure switch detectionP4Reverse phase or open phase errorP5System down due to frozen heat exchangerP6Error of momentary power failureP7Compressor down due to protection control of high pressure sensorP701Float switch detection error (low level riskP702Indoor unit EEV closing error (low level risk).P703Indoor unit EEV opening error (low level risk).P704MCU Solenoid valve failure (low level risk).P8Compressor down due to protection control of low pressure sensorP9In removing frostPACompressor down due to protection control of condensation ratioqxOPEN/SHORT error of room sensor in xth indoor unit.rxOPEN/SHORT error of EVAP IN sensor in xth indoor unit.sxOPEN/SHORT error of EVAP OUT sensor in xth indoor unit.t1Error of outdoor temperature sensor (OPEN/SHORT)t2Error of COND TEMP sensor (OPEN/SHORT)t3Error of PWM Discharge TEMP sensor (OPEN/SHORT)t4Error of liquid refrigerant pipe (COND OUT) TEMP sensor (OPEN/SHORT)t5Error of OIL TEMP sensor (OPEN/SHORT)t6Error of SUCTION TEMP sensor (OPEN/SHORT)t7Error of high pressure sensor (OPEN/SHORT)t8Error of low pressure sensor (OPEN/SHORT)t9Error of fixed compressor discharge sensor (OPEN/SHORT)toError of low pressure sensor breakaway.tuError of high pressure sensor breakaway.vxError of fan starting for xth indoor unit.
Service modes (4)
- Error resetPress reset key KEY 3 (K3) on the outdoor unit PCB.
- Piping check displayPress KEY 5 (K5) on the outdoor unit PCB after piping check to display error information.
- S-NET diagnostic checkConnect S-NET to the DVM system; run test operation in cooling mode for at least 40 minutes.
- Test operationPress KEY 4 (K4) on the outdoor unit PCB to initiate test operation of all indoor units.