mypros+
Error code reference

Samsung Heat Pump Error Code E208

Suction temperature sensor breakaway

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E208 error code actually means

Your heat pump's suction temperature sensor is either loose, disconnected from the pipe it's supposed to monitor, or has failed electrically. The system detected that this sensor's readings were not changing the way they should over a 30-minute window, which triggered this alert. A technician will need to check that the sensor is properly clipped onto the refrigerant line and test it with a meter to determine if it needs replacement.

Diagnostic procedure

The full E208 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check if suction sensor and sensor holder are correctly attached; measure resistance value.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E208 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E208

Ranked by how often they cause this code
  1. 1Sensor detached from suction line
  2. 2Failed suction temperature sensor (thermistor)
  3. 3Damaged or corroded wiring and connector
  4. 4Control board not reading sensor signal correctly

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E208

What does E208 mean on a Samsung heat pump?
E208 indicates a suction temperature sensor breakaway fault. The system detected that the difference between the initial suction temperature reading and the current reading was less than 2°C for 30 consecutive minutes. This points to the sensor being physically detached from the suction line, a failed sensor, or a wiring issue preventing accurate temperature tracking.
Is it safe to run my heat pump while E208 is active?
Operating the heat pump with E208 active is not recommended. Without accurate suction temperature data, the control system cannot properly protect the compressor from conditions like liquid slugging or overheating. Continued operation under a faulty sensor condition risks compressor damage, which is a far more costly repair than addressing the sensor fault.
How much does it cost to repair a Samsung heat pump E208 error?
Repair costs depend on the root cause. If the sensor simply needs to be reattached to its holder, the cost is primarily a service call fee, typically in the range of $75 to $150. If the suction temperature sensor itself has failed and needs replacement, parts and labor combined generally range from $150 to $350. Control board replacement, if required, is a more significant expense and can range from $400 to $800 or more depending on the model.
Can I fix E208 myself, or do I need a technician?
A homeowner can visually check whether the suction temperature sensor and its holder are properly attached to the suction pipe, which is the first recommended diagnostic step. However, measuring resistance values and working near refrigerant lines and live electrical components is best handled by a qualified technician. If the sensor needs replacement, a technician should perform the work to ensure the correct part is fitted and the system is properly tested afterward.
Will resetting the heat pump clear the E208 error?
A reset may temporarily clear the error code, but if the underlying cause, such as a detached sensor or failed thermistor, has not been corrected, the fault will return once the system monitors suction temperature again over a 30-minute window. The root cause must be diagnosed and resolved before the error will clear permanently.

78,000+ service manuals · 160,000+ error codes · 55+ brands