Samsung Heat Pump Error Code E403

Compressor down by compression ratio control

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E403 error code actually means

Your Samsung heat pump shut itself off because the pressure difference between the high and low sides of the refrigerant system got dangerously out of balance and stayed that way for more than 10 minutes. This is a protective shutdown meant to prevent the compressor from being damaged. A technician will need to check refrigerant pressures and valve positions to find the root cause.

Diagnostic procedure

The full E403 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Connect S-net and manifold gauge; check if service valve is fully opened; compare S-net with manifold gauge readings.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E403 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E403

Ranked by how often they cause this code
  1. 1Closed or partially closed service valve
  2. 2Low refrigerant charge
  3. 3Refrigerant overcharge
  4. 4Blocked or fouled heat exchanger coil
  5. 5Faulty high or low pressure transducer

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E403

What does E403 mean on a Samsung heat pump?
E403 means the compressor has been shut down by the system's compression ratio protection control. The ratio of (High pressure + 1) divided by (Low pressure + 1) exceeded 8.5 for more than 10 minutes, triggering a protective shutdown. This is designed to prevent compressor damage from operating under extreme pressure imbalance. A technician should connect diagnostic tools and check refrigerant pressures and service valve positions to identify the underlying cause.
Is it safe to keep running my heat pump when E403 appears?
No, the unit has already shut down the compressor as a protective measure and should not be forced to restart repeatedly. Continuing to operate the system under conditions that cause an abnormal compression ratio risks serious compressor damage. Leave the unit off and have a technician diagnose the issue before resuming normal operation.
Will resetting the unit clear the E403 error code?
A power reset may temporarily clear the code and allow the compressor to restart, but the error will return if the underlying condition causing the high compression ratio is not corrected. Because the fault requires the ratio to exceed 8.5 for over 10 minutes before triggering, repeated resets without repair will continue to stress the compressor. A proper diagnosis and repair are necessary for a lasting resolution.
Can I fix E403 on my Samsung heat pump myself?
Some basic checks, like confirming that the service valves are fully open, can be done without specialized tools. However, diagnosing refrigerant charge issues, checking pressure transducers, and handling refrigerant require EPA certification and professional equipment such as a manifold gauge set and S-net diagnostic software. Most homeowners should contact a certified HVAC technician for this error.
How much does it cost to repair a Samsung heat pump showing E403?
Repair cost depends entirely on the root cause. A simple service valve adjustment or coil cleaning may cost only a service call fee, typically in the range of $75 to $200. Refrigerant leak repair and recharge can range from $200 to $600 or more depending on the refrigerant type and leak location. Pressure transducer replacement generally falls in the $150 to $400 range including parts and labor.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass