Model reference
Amana CRRL-5C
Microwave
1 document52 error codes18 service modes
Available documentation
Service Manual
- Service Manual - 1602696933 pg
MyPros+ Max
Diagnose your Amana CRRL-5C.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (52)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d21Locked runaway oven temperature exceeding 950°F.3d11Oven temperature sensor circuit is open.3d21Oven temperature sensor circuit is shorted.3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch reports both locked and unlocked simultaneously.E-20Keyboard assembly fault indicating a failed control circuit or membrane switch…F1Internal board failure (LCC 90/95)F1E0Internal board failure.F1E1Indicates a Cycle Control Unit (CCU) problem.F1E2Internal board failure.F2A/D Error(s)F2E0Shorted key.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface software errorView all 52 error codes
F3Oven sensor opened or shorted, or bake/broil/clean range over temperature (LCC…F3E0Oven sensor opened.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<20 ohms).F3E5Inlet and exhaust thermistors are open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted/low air flow that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at installation.F5Door and switches do not agree or door latch not operating during clean mode…F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…F9Miswired house or miswired range (LCC 90/95).F9E0Miswired house or miswired range.L2Low L2 voltage (less than 50V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (18)
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- Customer-Focused Dryness Level Adjustment1
- Demo Mode1
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press individual keypads to test control relays
- Display Test1
- Faults Access1
- Install Diagnostics1
- Loads Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Within 5 seconds
- Quick Test Mode (EOC III)1
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Mode1
- Software Version Display1
- Software Versions Access1
- Temperature Adjustment ModeStep 1
- User Interface Test1
- User Interface/Control System Test1. Activate Service Diagnostic Mode. 2. Press and release the 1st button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass