Model reference
Amana TAA300/P77040-1W
Washer
7 documents80 error codes9 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10589885 - Rev B24 pg
- Maytag Amana Top Load Washer SAV5710AW SAV365ZAW SAV3655AW SAV3710AW Tech Sheet11 pg
- Domestic Washer Technical Information11 pg
- Tech Sheet W10750900 Rev C12 pg
Service Manual
- service manual W1133862052 pg
Installation Guide
- Instrucciones de instalacion36 pg
- Installation Instructions11 pg
MyPros+ Max
Diagnose your Amana TAA300/P77040-1W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (80)
CodeMeaning
:Flashing colon indicates a power failure has occurred.1-1Control detected K400 pilot relay stuck on.1-2Damaged or corrupted memory / software issue on control board.10-1Dispenser electrical problem10-2Vent wax motor electrical problem (not all models)10-3Drying fan error (on models with fan)2-1Control detected stuck key(s) in keypad or keypad connection.2-2User Interface cannot communicate with main control (no response from UI).3-1Thermistor/OWI open3-2Thermistor/OWI shorted3-3Thermistor/OWI failed calibration.4-1Wash motor failure4-3Wash motor not running5-1Door switch stuck open5-2Door switch stuck closed6-1Inlet water low/no water (mechanical problem)6-2Fill valve electrical problem6-3Suds/air in pump6-4Float switch open6-6Cool water6-7Disconnected or damaged flowmeter.6-8Water softener regen valve electrical problem (water softener models only)7-1No heat7-2Heater stuck on8-1Slow drain8-2Drain motor electrical problem8-3Drain motor not running (implied from context of draining errors).8-4Drain motor electrical problem9-1Diverter can't find position9-2Diverter stuck onView all 80 error codes
9-3Control detected diverter disk in sump is missing.9-4Lower spray arm errorE0Manufacturing codeE1Manufacturing codeE2Manufacturing codeE3Manufacturing codeE4Ice maker errorE5Ice maker errorE6Manufacturing codeErManufacturing codeF1:CFHardware configuration mismatch between electronic control board and display…F1:E4Microwave relay failure.F1:PrSoftware type mismatch in electronic control board.F10E1Dispenser electrical problem; loose connection in Dispenser Circuit and/or open…F10E2Vent wax motor electrical problem; loose connection in vent circuit and/or open…F10E3Drying fan error; loose connection in fan circuit and/or open fan motor (on…F1E1Control detected K400 pilot relay stuck closed.F1E2Damaged or corrupted memory on control board (control software issue).F2Touch panel failure.F2:E1Keyboard failureF2E1Control detected stuck key(s) in keypad or keypad connection.F2E2User Interface cannot communicate with main control; loose User Interface…F3E1Open connector or component in Temperature Sensing Circuit (open or faulty…F3E2Incoming water temperature above 167°F (75°C) or shorted connection/component…F3E3OWI sensor failed calibration.F3HHumidity sensor failure.F4:E1Magnetron temperature sensor failure (software error).F4E4Loose connection in Wash Motor Circuit and/or open wash motor; motor fuse open…F5E1Door was not latched within 3 seconds of pressing Start/Resume, or loose…F5E2Control programmed to not start if it suspects the door switch is stuck closed…F6MW relay failure (Relay 4903 contact may have welded closed).F6:E0Communication error between display board and electronic control board.F6E1No water to dishwasher (low/no water mechanical problem).F6E2Fill valve electrical problem; loose connection in Fill Valve Circuit and/or…F6E3Suds or air detected in pump.F6E4Float switch stuck in overfill (open) position and/or dishwasher not level.F6E7Disconnected or damaged flowmeter.F6E8Loose connection in Regen valve circuit, and/or open Regen valve solenoid…F7E1No heat; control disabled heater due to detected water heating problem, or open…F7E2Heater stuck on; heater drive circuit on the control failed.F8E1Slow drain; obstructed drain hose or path.F8E3Drain pump impeller fractured or damaged.F8E4Drain motor electrical problem; loose connection in Drain Motor Circuit and/or…F9E1Diverter can't find position; corroded or loose connection in diverter…F9E2Diverter stuck on; diverter drive circuit on the control failed.F9E3Control detected diverter disk in sump is missing.F9E4Lower spray arm error; mechanical binding/blocking or corroded/loose connection…noCFSoftware configuration error in display board.NTC OPEN, CALL FOR SERVICEHood thermistor open circuit.NTC SHORT, CALL FOR SERVICEHood thermistor shorted.
Service modes (9)
- Clear Customer Error History["Enter Service Diagnostics Cycle.","During the first interval, press HI TEMP key to clear customer…
- diagnostic["Plug in microwave oven or reconnect power.","Press Stop button to enter standby (displays…
- Forced Defrost Mode (Service Test 38)1. Enter Service Diagnostics Mode. 2. Navigate to Step 38. 3. Select SW3 to toggle
- Rapid Advance (Customer Cycle)["Start a customer cycle.","Press HIGH TEMP
- Sales Demo Mode ExitRun Service Diagnostics Cycle to clear Demo mode.
- Self-Diagnostic / Test Mode["1
- Self-diagnostic test mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
- Service Diagnostics Cycle["Press START/RESUME to wake up control panel.","Press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3…
- Service Diagnostics Mode1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana washer models
78,000+ service manuals · 160,000+ error codes · 55+ brands