Range
8 documents18 error codes13 service modes
Available documentation
Service Manual
- Built-In Oven Self-Cleaning Oven with Trivection™ Owner's Manual48 pg
- GE Oven JS998 JT930 JT980 Mini Manual 31 14136 14 pg
- TECHNICAL SERVICE GUIDE - 2003 Slide-In, Single and Double Wall Ovens with TrivectionTM Cooking77 pg
- GE Consumer Products Technical Service Guide 2003 Slide-In, Single and Double Wall Ovens with TrivectionTM Cooking77 pg
- TECHNICAL SERVICE GUIDE - Slide-In, Single and Double Wall Ovens with Trivection™ Cooking77 pg
Tech Sheet
- Appliance Diagnostic Modes Range GE Consumer & Industrial Technical Training255 pg
Installation Guide
- Installation Instructions - 30" Built-In Trivection™ Wall Oven16 pg
Other
- 319115GE2003SlideInSingleDblWallOvenswTrivectionCking77 pg
MyPros+ Max
Diagnose your GE JT980.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (18)
CodeMeaning
ENTERING SALES MODEDuring power-up, L1-L2 is between 90VAC and 150VAC and L1-N is between 90VAC…ERRA temperature was set outside the allowable range of 170°F–550°F.FFunction error code indicated by 'F' followed by a number or letter flashing in…F0Keyboard errorF2Temperature RunawayF3Open sensor/RTD circuit detected.F4Shorted sensor/RTD circuit detected.F5Control Sensor CircuitF7Stuck or shorted function key on the keypad.F8EEPROM data error.F9Thermal switch (FAD TCO) has opened in any mode of operation, indicating a…FCDoor Latch ErrorFdDisplay Error.FFLoss of latch motor safety circuit.LOW POWERAfter power-up, L1-L2 voltage drops below 150VAC during operation.SENSE 120V ENTERING SALES MODEDuring power-up, L1-L2 is between 90VAC and 150VAC and L1-N is between 90VAC…SUPPLY MISWIREDPower monitor detects miswired supply; L1-L2 is below 90VAC while L1-N is above…SUPPLY OPEN NEUTRALPower monitor detects open neutral condition; L1-N voltage is below 90VAC.Service modes (13)
- Control Lockout["Press the CONTROL LOCKOUT keypad for 3 seconds."]
- Factory Mode (Control Type Re-entry)["Enter special modes screen by pressing 0803 within 5 minutes of reconnecting power.","Press…
- Factory Mode (Control Type Selection)["Reconnect power to the oven.","Enter 0803 within 5 minutes of reconnecting power.","Press…
- Factory Mode (Oven Type Selection)["Within 5 minutes of reconnecting power, enter 0803 on the keypanel.","Press Factory1 to enter the…
- J2S968/JGS968/JGSP48 Fault Code Recall["Press TIMER, CLOCK, and MIN DOWN (or 9) key to get Fault Codes to appear."]
- JB905/968/988 Fault Code Recall["Press TIMER and CLOCK (or 9) key to get Fault Codes to appear."]
- JP938/JP968 Cooktop Calibration Mode["Clear everything from the top of the glass.","Lock the control by pressing the LOCK key for 3…
- JP938/JP968 Cooktop Technician Mode["Lock cooktop by holding CONTROL LOCK key for 3 seconds.","Control will beep 2 times and LOCK…
- LOC REF Procedure (JCK915/JCT915/JK915/JT915/JK955/JT955/ZEK938/ZET958)["Reinitiate LOC REF procedure by pressing BAKE/BROIL simultaneously.","For digital keypads press 9…
- Sabbath Mode["Access through the Features menus.","Press the keypad next to SABBATH."]
- Sales Mode["Power up with 120V only (L1-L2 = 120V, L2 connected to N).","Requires special 120 VAC cord (Wall…
- Service Mode["Disconnect main power to the oven for at least 15 seconds.","Reconnect power.","Enter 0803 on the…
- Trivection Service Mode["Disconnect main power to the oven for at least 15 seconds.","Reconnect power and enter 0803 on…
Full entry steps, exit procedures, and test sequences are available in Max.