Model reference

GE CYE23TS

Refrigerator

4 documents95 error codes7 service modes

Available documentation

Service Manual

  • Technical Service Guide63 pg
    Covers this model
  • ServiceManual CC CafeBFRefrigerator89 pg
    Covers this model
  • GE Cafe French Door Refrigerators with Hot Water Technical Service Guide63 pg
    Covers this model

Training

  • 2013 CAFÉ and Built-in Style French Door Refrigerator82 pg
    Covers this model
MyPros+ Max

Diagnose your GE CYE23TS.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (95)

View all 95 error codes
F304FZ Temp Exceeded.F305Dampers Stuck Closed.F306Damper Stuck Open.F3083 Way Valve Position Lost.F4FZ Evaporator Thermistor Invalid.F400Main Board FailureF401Ice/water stops dispensing based on time (7 Minute Timeout); only on SxS models…F403Main Board software failure.F404Main Board hardware failure.F5FP/Deli Pan Thermistor Invalid.F500Can't reach Target Hot Water Temp.F501Flow meter missingF502Flow meter pulsing with no water dispensingF503Ice/water stops dispensing based on 7 minute time out.F504Can't fill hot water tankF507Cold Water paddle switch input missing.F508Cold Water paddle switch input present when it should not be.F509Hot Water T&P Switch input missing.F510Hot Water T&P Switch input present when it should not be.F511Door Board Icemaker Mold temp invalid.F512Door Board Ice Box Thermistor invalid.F513Door Board Hot Water 1 Thermistor invalidF514Door Board Hot Water 2 Thermistor invalidF515Door Board relay driver shorted.F516Hot Water Thermistor FaultF517Hot Water AD Voltage Reference Voltage Fault.F518Hot Water Low Flow RateF519Hot Water heating when tank not full.F520Maximum Fill Time OutF521Maximum Purge Time OutF522Hot Water Maximum Purge Time OutF6FF Evaporator Thermistor Invalid.F600FF Icemaker Multi-fill active 3 times in the last 10 fills.F601FF Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F602FF Icemaker enters harvest fix mode 3 out of 10 harvests.F603FF Icemaker enters Fault Mode after entering Harvest Fault.F604FF Icemaker no water supply detectedF605FF Icemaker continues to sense bucket full after ice dispenseF606FF Icemaker Mold heater not heatingF650FZ Icemaker Multi-fill active 3 times in the last 10 fills.F651FZ Icemaker Stuck in Harvest Fix Mode (after 10 minutes stuck in Harvest Fix…F652FZ Icemaker enters harvest fix mode 3 out of 10 harvests.F653FZ Icemaker enters Fault Mode after entering Harvest Fault.F7Convertible Drawer Thermistor Invalid.F700Stuck keys on ICID/ACM (Dispenser Boards).F701Stuck Keys on Internal Temp Board.F702Stuck Keys on Deli Pan.F703Key inputs on Deli Pan Temp Board and Door Closed (FF Door is closed and a Key…F704Key Inputs on Deli Pan/FP Board and Door Closed (FF Door is closed and a key…F705Auto fill Communication Error (AutoFill Module not communicating properly).F706Auto fill wrong version (not compatible with the ACM Version).F707ACM/Comm Communication Error (COM Module not communicating properly).F708COM Wrong Version (not compatible with the ACM).F709Cold Water Cup Switch Input missing and 0x70 message is received from COM (ACM…F710Cold Water Cup Switch Input present and no dispense message is received from…F711Hot Water Cup Switch Input missing and dispense message is received that…F712Hot Water Cup Switch Input present and no dispense message is received (ACM…F713FF Door open for 15 minutes without closing.F714FF Door open for 60 minutes in the last 24 hours.F71550 FF Door Openings in the last 24 hours.F716FZ Door open for 15 minutes without closing.F717FZ Door open for 60 minutes in the last 24 hours.F71850 FZ Door Openings in the last 24 hours.F8Ambient Temperature Invalid.F9Ambient Humidity Invalid.

Service modes (7)

  • Cooling System Off ModeOn non-dispenser temperature control models, press and hold 'Refrigerator' and 'Freezer' buttons…
  • Dealer Demo ModePress Lock Controls and Precise Fill pads simultaneously for 3 seconds
  • Fault Code Display ModeEnter Service Mode (hold Water, Crushed, Cubed pads 3-5 seconds, press Yes)
  • Retrieve Failure CodesEnter Service Diagnostics mode (press and hold Water, Crushed & Cubed for 3 seconds, select Yes)
  • Sabbath ModePress and hold Lock Controls and Light buttons simultaneously for 3 seconds
  • Service Diagnostic ModePress and hold the Water, Crushed, and Cubed pads together for 3 to 5 seconds
  • Service DiagnosticsPress and hold 'Water', 'Crushed' & 'Cubed' pads together for 3 seconds to enter Service Mode

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax