Model reference
GE ZIS480NKC
Refrigerator
12 documents30 error codes16 service modes
Available documentation
Service Manual
- GE Monogram Side-By-Side Refrigerators With Electronic Controls Technical Service Guide72 pg
- TECHNICAL SERVICE GUIDE Monogram Inverter Compressor Side-By-Side Refrigerators63 pg
- TECHNICAL SERVICE GUIDE - Monogram Inverter Compressor Side-By-Side Refrigerators63 pg
- GE Appliances Technical Service Guide - Monogram® 36" 42" 48" Built-In Side By Side Refrigerators75 pg
Bulletin
- Service Bulletin - Refrigerators 48" Non-Dispenser Side-By-Side Models Ice Deflector1 pg
- Monogram Side by Side Non Dispenser Models - Ice cubes hanging up between the Icemaker and the rear duct FZ1 pg
- Service Bulletin - Refrigerators Monogram Side-by-Side Light Switch Replacement1 pg
- Monogram Side by Side Dispenser Models Auger Motor Stalling1 pg
- GE Monogram Refrigerators - Service Bulletin2 pg
Training
- TECHNICAL SERVICE GUIDE Monogram Side-By-Side Refrigerators With Electronic Controls72 pg
- TECHNICAL SERVICE GUIDE - Monogram Side-By-Side Refrigerators With Electronic Controls65 pg
- Built-in SXS Refrigerators Icemaker Operation and Diagnosis Training Bulletin TB06-17 Rev 11 pg
MyPros+ Max
Diagnose your GE ZIS480NKC.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (30)
CodeMeaning
0001FF1 thermistor reading out of range.0002FF2 thermistor reading out of range.0003FZ thermistor reading out of range.0004FZ evaporator thermistor reading out of range.0008Ambient temperature thermistor reading out of range.0013Quick Chill thermistor reading out of range.0100FZ fan feedback missing when the fan is running.0101FZ fan feedback present when fan is off.0102FZ fan cannot reach target speed.0200FZ defrost heater timed out (check FZ evaporator thermistor fault code 0004).02025 consecutive FZ abnormal defrosts.0300Compressor ran continuously for 24 hours.0301Temperature satisfied greater than 3 hours with no compressor operation.0302FF temperature below freezing.0303FF temperature exceeds 20°F over setpoint, 1 hour post defrost or door opening.0304FZ temperature exceeds 20°F over setpoint, 1 hour post defrost or door opening.0307Damper driver fault (not available on some software versions).0401Dispenser paddle switch pressed for more than 7 minutes.0403Mainboard software fault.0404Mainboard hardware fault.0654FZ icemaker no water supply detected.0700Stuck keys on dispenser boards.0701Stuck keys on internal temperature board.0703Key press on temperature board while door is closed.0713FF door open for 15 minutes continuously.0714FF door open for 60 minutes total in the last 24 hours.071550 FF door openings in the last 24 hours.0717FZ door open for 15 minutes continuously.0718FZ door open for 60 minutes total in the last 24 hours.071950 FZ door openings in the last 24 hours.Service modes (16)
- 100_percent_run_timeIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 2, then press any pad other…
- communication_check_dispenser_to_main_boardIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 4, then press any pad other…
- communication_check_temp_control_to_dispenserIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 3, then press any pad other…
- communication_check_temp_control_to_main_boardIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 2, then press any pad other…
- control_and_sensor_system_self_testIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 7, then press any pad other…
- dampers_testIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 0, then press any pad other…
- defrost_testIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 4, then press any pad other…
- degree_c_f_toggleIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 7, then press any pad other…
- diagnosticPress both the freezer temperature pads (plus and minus) and the refrigerator temperature pads…
- Diagnostic ModePress both freezer temperature pads (+ and -) and the refrigerator temperature pads (+ and -)…
- dispenser_recess_heater_testIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 9, then press any pad other…
- hmi_self_testIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 6, then press any pad other…
- main_control_resetIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 5, then press any pad other…
- open_duct_door_testIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 8, then press any pad other…
- pre_chill_testIn diagnostic mode, set Freezer Display to 1 and Fresh Food Display to 3, then press any pad other…
- showroom_modeIn diagnostic mode, set Freezer Display to 0 and Fresh Food Display to 1, then press any pad other…
Full entry steps, exit procedures, and test sequences are available in Max.
Related GE refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass