Model reference
LG AMNH096TEC0
Air Conditioner
9 documents34 error codes40 service modes
Available documentation
Service Manual
- Multi Type Air Conditioner SERVICE MANUAL249 pg
- LG Multi Type Air Conditioner SERVICE MANUAL248 pg
- Multi Type Air Conditioner SERVICE MANUAL248 pg
- Multi Type Air Conditioner SVC MANUAL (Exploded View)255 pg
- Multi Type Air Conditioner SVC MANUAL(Exploded View)261 pg
- Multi Type Air Conditioner SVC MANUAL (Exploded View)254 pg
- Multi Type Air Conditioner SVC MANUAL (Exploded View)237 pg
- Multi Type Air Conditioner SVC MANUAL (Exploded View)261 pg
Other
- LG Samsung AMNH076LQL0 AMNH096LQL0 AMNH096LRL0 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0 AMNH07GD4L0 AMNH09GD4L0 AMNH12GD4L0 AMNH18GD5L0 AMNH24GD5L0261 pg
MyPros+ Max
Diagnose your LG AMNH096TEC0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (34)
CodeMeaning
01Indoor room thermistor (air sensor) error02Indoor inlet pipe sensor error03Communication error between indoor unit and wired remote controller.04Drain pump or float switch error05Communication error between indoor and outdoor units.06Indoor outlet pipe sensor error07Different mode operation error105Communication error between main board and fan board.21DC Peak / IPM Fault22Max CT23DC Link low voltage24Low/High pressure switch open.25Low voltage or over voltage at input power supply.26DC compressor position error27PSC fault error28DC link high voltage32Inverter discharge pipe temperature high (over 105°C).33Normal (constant) compressor discharge pipe temperature high.40CT sensor error41Inverter discharge pipe thermistor error44Outdoor air thermistor error45Condenser pipe sensor error46Suction pipe sensor error47Constant compressor discharge pipe thermistor error51Over capacity52Communication error between main micom and sub micom on outdoor PCB.53Communication error between indoor and outdoor units (outdoor side indication).54Outdoor 3-phase power supply error60EEPROM check sum error.61Condenser pipe temperature high (over 65°C).Service modes (40)
- Address Monitoring (Wireless Remote)Press Chaos Swing (6) and Reset (13) keys simultaneously to enter Address Monitoring Mode
- Address Monitoring Mode (Wireless Remote)Press Chaos Swing (button 6) and Reset (button 13) simultaneously.
- Address Setting Mode (Wired Remote)Press Program (button 13) and Set/Clear (button 16) simultaneously for more than 3 seconds. Set…
- Address Setting Mode (Wireless Remote)Press Jet Cool (button 5) and Reset (button 13) simultaneously for more than 3 seconds. Set address…
- address_monitoring["Press Chaos Swing (button 6) and Reset (button 13) simultaneously to enter Address Monitoring…
- address_monitoring_wireless["Press Chaos Swing (6) and Reset (13) keys simultaneously to enter Address Monitoring Mode","Press…
- address_setting_wired_remocon["Press Program (13) and Set/Clear (16) keys simultaneously for more than 3 seconds to enter…
- address_setting_wired_remote["Press Program (button 13) and Set/Clear (button 16) simultaneously for more than 3 seconds to…
- address_setting_wireless_remocon["Press Jet Cool (5) and Reset (13) keys simultaneously for more than 3 seconds to enter Address…
- address_setting_wireless_remote["Press Jet Cool (button 5) and Reset (button 13) simultaneously for more than 3 seconds to enter…
- E.S.P. (External Static Pressure) Setting1
- ESP (External Static Pressure) Setting (Duct Type)1
- ESP (External Static Pressure) Setting Mode1
- ESP Setting Mode (Duct Type)1
- ESP Setting Mode (Duct/Cassette Wired Remote)1
- ESP Setting Mode (Duct/CST Wired Remote)1
- esp_setting_duct["Push On/Off button to start unit","Push Timer and Wind buttons simultaneously for more than 3…
- Forced Operation (Cassette Type)Press the operation button for 2 seconds.
- Forced Operation (Indoor Unit)Set the slide switch on the main unit to the forced operation position
- Forced Operation (Main Unit)Set the slide switch on the main unit to the forced operation position while power is on, or supply…
- Forced Operation (Room Type)Set the slide switch on the main unit from remote control position to the forced operation…
- Forced Operation (Slide Switch)Set the slide switch on the main unit to the forced operation position while power is on, or supply…
- Forced Operation (Wall Mounted)Switch the slide switch on the main unit from the remote control position to the forced operation…
- forced_operation["Switch slide switch on main unit from remote control position to forced operation…
- forced_operation_cassette["Press button for 2 seconds to start forced operation (Cassette Type)"]
- Indoor Unit Address Setting (Wired Remote)1
- Indoor Unit Address Setting (Wireless Remote)1
- Test Run (Cassette Type - Start by button press)Press the forced operation button for 2 seconds for forced operation
- Test Run (Cassette Type - Wired Remote)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Cassette Type)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Cassette Wired Remote)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (CST Type - Wired Remote)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (CST Wired Remote)Press the room temperature checking button and down timer button simultaneously for 3 seconds.
- Test Run (Room Type)Press the timer cancel button five times continuously on the remote control.
- Test Run Start (Cassette Type)Press the operation button for 5 seconds.
- test_run_cassette["Press room temperature checking button and down timer button simultaneously for 3 seconds"]
- test_run_cassette_type["Press the forced operation button for 5 seconds"]
- test_run_cassette_type_forced["Press the forced operation button for 2 seconds"]
- test_run_cassette_wired_remote["Press the room temperature checking button and down timer button simultaneously for 3 seconds"]
- test_run_room_type["Press timer cancel button five times continuously"]
Full entry steps, exit procedures, and test sequences are available in Max.
Related LG air conditioner models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax