Model reference
Maytag RJDO3003A
Oven
2 documents40 error codes4 service modes
Available documentation
Tech Sheet
- Electric Wall Oven—Technical Information11 pg
Bulletin
- Technical Bulletin - Hinge and Receptacle Modification1 pg
MyPros+ Max
Diagnose your Maytag RJDO3003A.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (40)
CodeMeaning
1c1cShorted key detected on control board.1c2cKeyboard tail disconnected from control board.1c31Cancel key circuit problem (upper cavity or single oven).1c32Cancel key circuit problem (lower cavity).1c4cPower micro communication failure (CRC invalid).1c5cVCC or ground open circuit detected when cook or clean is programmed.1c6cEEPROM error, no response from EEPROM.1c7cControl not calibrated, calibration value out of range.1c81Cook profile corrupted in EEPROM (CRC invalid, upper cavity).1c82Cook profile corrupted in EEPROM (CRC invalid, lower cavity).1c8cCook profile corrupted in EEPROM (CRC invalid).1d11Runaway temperature (650°F) detected with door unlocked, upper oven.1d12Runaway temperature (650°F) detected with door unlocked, lower oven.1d21Runaway temperature (950°F) detected with door locked, upper oven.1d22Runaway temperature (950°F) detected with door locked, lower oven.3d11Temperature sensor failure (open) in upper oven, resistance greater than…3d12Temperature sensor failure (open) in lower oven, resistance greater than…3d21Temperature sensor failure (short) in upper oven, resistance less than 0 ohms.3d22Temperature sensor failure (short) in lower oven, resistance less than 0 ohms.3d41Meat probe shorted in upper cavity, probe resistance less than 0 ohms.3d42Meat probe shorted in lower cavity, probe resistance less than 0 ohms.3d51Meat probe not calibrated, calibration value out of range.4d11Door switch position failure, door switch not closed when door is locked (upper…4d12Door switch position failure, door switch not closed when door is locked (lower…4d21No Reverse Airflow Fan rotation (no or low RPM) in upper oven.4d22No Reverse Airflow Fan rotation (no or low RPM) in lower oven.4d31Reverse Airflow Fan state error, fan on when supposed to be off (upper cavity).4d32Reverse Airflow Fan state error, fan on when supposed to be off (lower cavity).4d41High Reverse Airflow Fan rotation (high RPM) in upper oven.4d42High Reverse Airflow Fan rotation (high RPM) in lower oven.View all 40 error codes
4d51Door switch circuit failure, switch not reading open or closed (upper cavity).4d52Door switch circuit failure, switch not reading open or closed (lower cavity).9d11Motorized door latch will not lock, lock switch not closed (upper cavity).9d12Motorized door latch will not lock, lock switch not closed (lower cavity).9d21Motorized door latch will not unlock, unlock switch not closed (upper cavity).9d22Motorized door latch will not unlock, unlock switch not closed (lower cavity).9d31Latch both locked and unlocked simultaneously (upper cavity).9d32Latch both locked and unlocked simultaneously (lower cavity).9d41Latch neither locked nor unlocked (upper cavity).9d42Latch neither locked nor unlocked (lower cavity).
Service modes (4)
- Control Lockout["Press and hold BACK and SETUP pads for 5 seconds."]
- Demo Mode["Press SETUP pad.","Press DOWN ARROW pad to scroll to DEMO.","Select DEMO to activate.","Press…
- Diagnostic Code Display Mode["Press SETUP pad.","Press DOWN ARROW pad three times until SERVICE is displayed.","Press SERVICE…
- Test Mode["Press SETUP pad.","Press DOWN ARROW pad three times until SERVICE is displayed.","Press SERVICE…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag oven models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass