mypros+
Model reference

Maytag MER6765BAB

Range

5 documents58 error codes24 service modes

Available documentation

Tech Sheet

  • Tech Sheet - 1602735910 pg
    Covers this model

Service Manual

  • Freestanding Double Oven Electric Range85 pg
    Covers this model
  • Service Manual85 pg
    Covers this model
  • Service Manual - Freestanding Double Oven Electric Range85 pg
    Covers this model
  • Maytag Freestanding Double Oven Electric Range Service Manual85 pg
    Covers this model
MyPros+ Max

Diagnose your Maytag MER6765BAB.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (58)

CodeMeaning
1c1cShorted key detected on control circuit board.1c2cKeyboard tail disconnected; keyboard loop reading improper value.1c31Cancel key circuit problem (upper oven / single cavity); cancel key reading…1c32Cancel key circuit problem (lower oven); cancel key reading improper value.1c4cMicro communication failure.1c5cVCC or ground fault on control circuit board.1c6cEEPROM error; no response from EEPROM after 3 tries.1c7cControl not calibrated; calibration value out of range after 3 tries.1c8cCooking program error; CRC invalid after 3 tries.1d11Runaway temperature (650°F) detected with door unlocked in upper oven; sensor…1d12Runaway temperature (650°F) detected with door unlocked in lower oven; sensor…1d21Runaway temperature (950°F) detected with door locked in upper oven; sensor…1d22Runaway temperature (950°F) detected with door locked in lower oven; sensor…3d11Temperature sensor open in upper oven (or single cavity); sensor resistance…3d12Temperature sensor open in lower oven; sensor resistance reads infinite ohms.3d21Temperature sensor shorted in upper oven; sensor resistance reads 0 ohms.3d22Temperature sensor shorted in lower oven; sensor resistance reads 0 ohms.4d11Door switch position failure (upper); door switch not closed when door is…4d12Door switch position failure (lower); door switch not closed when door is…4d21No reverse airflow fan rotation (no or low RPM) when convection cook or clean…4d31Reverse airflow fan is on when it should be off.4d51Door switch circuit failure (upper); door switch not reading open or closed.4d52Door switch circuit failure (lower); door switch not reading open or closed.9d11Door latch will not lock in upper oven; lock switch not closed.9d12Door latch will not lock in lower oven; lock switch not closed.9d21Door latch will not unlock in upper oven; unlock switch not closed.9d22Door latch will not unlock in lower oven; unlock switch not closed.9d31Latch state unknown in upper oven; both locked and unlocked switches reading…9d32Latch state unknown in lower oven; both locked and unlocked switches reading…9d41Latch state unknown in upper oven; neither locked nor unlocked switch reading.
View all 58 error codes

Service modes (24)

  • 24-Hour Clock TogglePress and hold Upper Cancel and Delay pads for 3 to 5 seconds.
  • Beeper Volume AdjustmentHold Upper Cancel and More+ pads for 3 seconds.
  • Child Lock OutPress and hold Upper Cancel and Cook & Hold pads for 3 to 5 seconds
  • Clock Display TogglePress and hold Upper Cancel and Clock pads for 3 to 5 seconds.
  • Demo ModePress and hold Upper Cancel and Less- pads for 3 to 5 seconds.
  • Diagnostic Code DisplayPress and hold UPPER CANCEL and TIMER pads for 3 to 5 seconds within 5 minutes of power up
  • Diagnostic Code Display Mode (H2 Control - MER6875A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and UPPER BROIL pads for 3…
  • Diagnostic Code Display Mode (H2 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and UPPER BROIL for 3 seconds within 5 minutes…
  • Diagnostic Code Display Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)["Must be within 5 minutes of power-up.","Press and hold UPPER CANCEL and TIMER pads for 3…
  • Diagnostic Code Display Mode (H3 Control)Enter Quick Test Mode (press and hold UPPER CANCEL and TIMER for 3 seconds within 5 minutes of…
  • Engineering Test Mode["Press BAKE pad.","Enter 100°F using the number pads.","Immediately push and hold BAKE pad for…
  • Factory Default ResetPress and hold Upper Cancel and Warm pads for 3 to 5 seconds.
  • Oven Temperature Adjustment - Lower Oven1
  • Oven Temperature Adjustment - Upper Oven1
  • Quick Test ModePress and hold UPPER CANCEL and UPPER BROIL pads for 3 to 5 seconds
  • Quick Test Mode - Component ActivationPress and hold UPPER CANCEL and BROIL pads for 3 seconds
  • Quick Test Mode (H2 Control - MER6875A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and UPPER BROIL pads for 3 seconds
  • Quick Test Mode (H3 Control - MER6555A**, MER6751AA*, MER6755A**, MER6775A**)Within 5 minutes of power-up, press and hold UPPER CANCEL and TIMER pads for 3 seconds.
  • Quick Test Setup Options["Enter Quick Test Mode first.","Press the 0 pad.","'Press Desired Pad for Selection' will scroll…
  • Sabbath ModeHold Clock pad for 3 to 5 seconds to activate
  • Setup Options ModeWhile in Quick Test Mode, press the 0 pad
  • Temperature Display Toggle (F/C)Press and hold Upper Cancel and Upper Bake pads for 3 to 5 seconds.
  • Test Mode["Must be activated within first 5 minutes of power up.","Press BROIL and CANCEL pads for…
  • Test Mode (ERC)Must be activated within the first 5 minutes of power up

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started