mypros+
Model reference

Samsung RF22K9588SG

Refrigerator

3 documents75 error codes11 service modes

Available documentation

Service Manual

  • REFRIGERATOR FRENCH DOOR REFRIGERATOR Technical Service Guide154 pg
    Covers this model
  • Samsung Service Manual RF22K9381SG XAA RF22K9381SR XAA RF23J9011SG XAA RF23J9011SR XAA RF23J9018SR XAA104 pg
    Covers this model

Bulletin

  • Door Open Errors Due to Broken Bottom Hinge Cover(s)1 pg
    Covers this model
MyPros+ Max

Diagnose your Samsung RF22K9588SG.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (75)

View all 75 error codes
5EFridge compartment defrosting sensor error61CIce duct heater error65CIce bucket heater error66CDoor handle heater error6CAmbient sensor error6EExternal air sensor error71CFreezer abnormal temperature error72CFridge abnormal temperature error73CConvertible zone chill error7CConvertible zone sensor error7ECool Select Room sensor error81CCompressor run error.82CCompressor IPM fault.83CCompressor current error.84CCompressor motor stall.85CCompressor low voltage error86CCompressor high voltage error93CCompressor error (grouped with 81-86 compressor errors on location image).9CConvertible zone defrost sensor errorC-Fan ErrorCompressor cooling fan motor feedback signal line contact error, motor wire…Cool Select Room defrosting sensor errorCool Select Room defrosting sensor errorCool Select Room Fan ErrorCool Select Room fan motor feedback signal line contact error, motor wire…Door Handle Heater ErrorDoor handle heater open error.F Comp IPM Fault ErrorFreezer compressor IPM fault error has occurred.F Comp location detection errorFreezer compressor location detection failed.F Comp low voltage errorFreezer compressor AC input voltage is too low (AC 106V or lower).F Comp motor constraint errorFreezer compressor motor is constrained.F Comp over voltage errorFreezer compressor AC input voltage is too high (AC 310V or higher).F Comp start failure errorFreezer compressor has failed to start.Freezer Fan ErrorFreezer fan motor feedback signal line contact error, motor wire separation or…Fridge Fan ErrorFridge fan motor feedback signal line contact error, motor wire separation or…Fridge Ice Bucket Heater ErrorIce bucket heater connector slipped out, open contact, wire cut…Fridge Ice Duct Heater ErrorIce duct heater connector slipped out, open contact, wire cut, short-circuited…Ice Maker (Fridge) Sensor ErrorIce Maker sensor connector slipped out, open contact, wire cut…Ice Maker Fan ErrorIce Maker fan motor feedback signal line contact error, motor wire separation…Ice Maker Function ErrorIce Maker defect in removing ice cubes or making it paralleled; error during…OP ChPanel to Main MICOM option change error.OP ErPanel to Main MICOM option error.Pc ErCommunication error between Panel PCB and Main MICOMR Comp IPM fault errorFridge compressor IPM fault error has occurred.R Comp location detection errorFridge compressor abnormal current detected (location detection failed).R Comp low voltage errorFridge compressor AC input voltage is too low (AC 106V or lower).R Comp motor constraint errorFridge compressor motor is constrained.R Comp over voltage errorFridge compressor AC input voltage is too high (AC 310V or higher).R Comp start failure errorFridge compressor has failed to start.

Service modes (11)

  • Engineer Mode - Fridge Function TestWithin 3 seconds, touch the 'A' area (upper left of display) and 'B' area (upper right of display)…
  • Engineer Mode - Panel Function TestWithin 3 seconds, touch the 'A' area (upper left of display) and 'B' area (upper right of display)…
  • Exhibition ModeTouch and hold Freezer, Fridge, and Door Alarm buttons simultaneously for 5 seconds during normal…
  • Force Run (Forced Operation / Forced Defrost)Enter Fridge Function Test (Engineer Mode)
  • Ice Maker Test ModePress and hold the Ice Maker Test Switch for more than 1.5 seconds.
  • Load Condition Display Mode1
  • Load StatusEnter Fridge Function Test (Engineer Mode)
  • Option Setting ModePress Door Alarm Key + Fridge Key simultaneously for 12 seconds during normal operation
  • Self DiagnosisEnter Fridge Function Test (Engineer Mode)
  • Self-Diagnostic ModePress Freezer Key + Fridge Key simultaneously for 8 seconds during normal operation
  • Test Mode (Manual Operating / Manual Defrosting)1. Touch Freezer Key + Cool Select+ Key simultaneously for 8 seconds (all displays turn off). 2…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started