Model reference

Sub-Zero ICBIW-24-LH

Wine Storage

2 documents50 error codes3 service modes

Available documentation

Service Manual

  • Sub-Zero Service Manual: ICB Integrated Wine Storage — Service Manual110 pg
    Covers this model

Parts Manual

  • Sub-Zero Parts Manual: ICB Integrated Wine Storage — Parts Manual33 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ICBIW-24-LH.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (50)

CodeMeaning
10 1 00Zone 1 (upper wine) cabinet thermistor open circuit.10 1 01Zone 1 (upper wine) cabinet thermistor short circuit.10 1 02Zone 1 (upper wine) cabinet thermistor unstable readings.10 1 10Zone 1 (upper wine) evaporator thermistor open circuit.10 1 11Zone 1 (upper wine) evaporator thermistor shorted.10 1 12Zone 1 (upper wine) evaporator thermistor unstable readings.10 2 00Zone 2 (lower wine) cabinet thermistor open circuit.10 2 01Zone 2 (lower wine) cabinet thermistor short circuit.10 2 02Zone 2 (lower wine) cabinet thermistor unstable readings.10 2 10Zone 2 (lower wine) evaporator thermistor open circuit.10 2 11Zone 2 (lower wine) evaporator thermistor shorted.10 2 12Zone 2 (lower wine) evaporator thermistor unstable readings.10 3 00Zone 3 (refrigerator) cabinet thermistor open circuit.10 3 01Zone 3 (refrigerator) cabinet thermistor short circuit.10 3 02Zone 3 (refrigerator) cabinet thermistor unstable readings.10 3 10Zone 3 (refrigerator) evaporator thermistor open circuit.10 3 11Zone 3 (refrigerator) evaporator thermistor shorted.10 3 12Zone 3 (refrigerator) evaporator thermistor unstable readings.10 7 00Ambient thermistor on control board is open.10 C 00Condenser thermistor open circuit detected.10 C 01Condenser thermistor short circuit detected.10 C 02Condenser thermistor unstable readings.15 1 00Zone 1 compressor relay stuck open; no current detected.15 1 01Zone 1 compressor relay stuck closed; 120V to compressor at all times.15 2 00Zone 2 compressor relay stuck open; no current detected.15 2 01Zone 2 compressor relay stuck closed; 120V to compressor at all times.15 3 00Zone 3 compressor relay stuck open; no current detected.15 3 01Zone 3 compressor relay stuck closed; 120V to compressor at all times.15 C 00AC condenser fan relay stuck open; no power to condenser fan.15 C 01AC condenser fan relay stuck closed; power to condenser fan at all times.
View all 50 error codes

Service modes (3)

  • Sabbath Mode["1
  • Service Options Mode["1. From the home screen, press the arrow icon to go to the Options screen.","2. Touch the…
  • Showroom Mode["1. On the home screen press the arrow icon.","2. Options screen is displayed. Touch the settings…

Full entry steps, exit procedures, and test sequences are available in Max.