mypros+
Model reference

Whirlpool W10143268

Dryer

2 documents25 error codes6 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10143268 - Rev A16 pg
    Covers this model
  • Tech Sheet W10143265A12 pg
    Covers this model
MyPros+ Max

Diagnose your Whirlpool W10143268.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (25)

CodeMeaning
AFLow inlet air flow detected at installation.F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted airflow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).L2Low line voltage (less than 30V) detected at installation.PFPower failure occurred while the dryer was running.

Service modes (6)

  • Customer-Focused Drying Mode Adjustment["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Inlet Air Flow Display Test["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Line Voltage Display Test["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…
  • Service Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes Dry…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass