Samsung Heat Pump Error Code E121

Detection of reverse phase or missing phase of 3-phase power

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the E121 error code actually means

Your Samsung heat pump is detecting a problem with the three-phase electrical power coming into the outdoor unit. Either the power lines are connected in the wrong order, or one or more of the power lines is not delivering electricity properly. This is an electrical supply issue that requires a licensed electrician or HVAC technician to diagnose and correct safely.

Diagnostic procedure

The full E121 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check power of 3-phase detection part on outdoor unit PCB; verify voltage between CN82 power cable terminals (red-white/white-black/red-black) is approximately 380V.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E121 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E121

Ranked by how often they cause this code
  1. 1Incorrect phase wiring order
  2. 2Missing or open phase from utility supply
  3. 3Blown or failed supply-side fuse
  4. 4Loose or corroded terminal connection
  5. 5Faulty phase detection circuit on outdoor PCB

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E121

What does E121 mean on a Samsung heat pump?
E121 indicates that the outdoor unit PCB has detected either a reversed phase sequence or a missing phase in the 3-phase power supply. The PCB monitors all three phases to protect the compressor and fan motors from running on incorrect or incomplete power. The system shuts down automatically when this condition is detected. A technician should measure the voltage at connector CN82 across all three terminal pairs to begin diagnosing the fault.
Is it safe to keep running my heat pump when E121 is showing?
No, the heat pump will not operate while E121 is active because the PCB shuts the system down upon detecting this condition. This shutdown is a protective function that prevents compressor and motor damage from reverse phase rotation or single-phase operation. Do not attempt to bypass or reset the protection circuit and resume operation until the underlying power supply issue has been corrected.
How much does it cost to repair a Samsung heat pump showing E121?
Repair costs vary depending on the cause. If the fault is a reversed phase connection, the cost is primarily a service call fee, typically in the range of $75 to $200, since the fix involves rewiring rather than replacing parts. A blown fuse replacement is inexpensive at $10 to $50 for parts, plus labor. If the outdoor unit PCB has failed and requires replacement, costs can range from $300 to $800 or more depending on parts and labor rates in your area.
Can I fix error E121 myself, or do I need a professional?
Diagnosing and repairing a 3-phase power fault involves working with 380V AC electrical systems, which is dangerous without proper training and equipment. A licensed electrician or certified HVAC technician should perform voltage measurements at the outdoor unit PCB, check phase wiring order, and inspect fuses and breakers. Homeowners should not attempt to open electrical panels or disconnect boxes to reorder phase conductors.
Will resetting the heat pump clear error code E121?
Resetting the unit will not permanently clear E121 if the root cause has not been corrected. The phase detection circuit will re-evaluate the incoming power on startup and will trigger E121 again if the phase order is still reversed or a phase is still missing. The fault must be resolved at the electrical supply level before the unit will operate normally.