What the E202 error code actually means

Your Samsung heat pump has shut itself off to prevent damage because the refrigerant pressure inside the system dropped too low. This is a protective feature that stops the compressor from running without enough refrigerant flow, which would burn it out. A technician will need to check for refrigerant leaks, blocked valves, or other issues affecting refrigerant circulation.

Diagnostic procedure

The full E202 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Connect S-net and manifold gauge; check if service valve is fully opened.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock E202 procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of E202

Ranked by how often they cause this code
  1. 1Partially closed service valve
  2. 2Low refrigerant charge due to a leak
  3. 3Dirty or blocked evaporator coil
  4. 4Faulty or stuck expansion valve
  5. 5Defective low pressure sensor

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about E202

What does E202 mean on a Samsung heat pump?
E202 means the heat pump compressor has been shut down by the low pressure protection control. The system detected refrigerant pressure below 2.6 kg/cm2G during cooling mode or below 1.4 kg/cm2G during heating mode. This is a protective shutdown designed to prevent compressor damage from operating without adequate refrigerant pressure. A technician should connect a manifold gauge set and S-net diagnostic tool to evaluate actual system pressures and identify the root cause.
Is it safe to keep running my heat pump when E202 is displayed?
No. The E202 code indicates the system has already shut down the compressor as a safety measure. Attempting to override or repeatedly restart the unit without addressing the low pressure condition can cause severe compressor damage, including burned motor windings or seized internal components. Leave the unit off until the underlying cause has been diagnosed and corrected.
Will resetting the Samsung heat pump clear the E202 error?
A power reset may temporarily clear the E202 code and allow the unit to restart, but if the underlying low pressure condition still exists, the system will detect it again and shut down. Resetting without fixing the root cause risks compressor damage over repeated attempts. The error should be diagnosed and resolved before returning the unit to normal operation.
Can I fix E202 on my Samsung heat pump myself?
Some basic checks are within reach for a knowledgeable homeowner, such as confirming that the service valves on the refrigerant lines are fully open. However, diagnosing and repairing refrigerant leaks, recharging refrigerant, or replacing components like expansion valves or pressure sensors requires specialized tools and EPA certification to handle refrigerants. It is recommended to contact a licensed HVAC technician for this fault.
How much does it cost to repair a Samsung heat pump showing E202?
Repair costs vary widely depending on the cause. If the fix is simply opening a closed service valve, labor costs alone may be in the range of $75 to $150. Refrigerant leak repair and recharge can run $200 to $600 or more depending on the leak location and refrigerant type. Replacing an expansion valve or low pressure sensor typically adds $150 to $400 in parts and labor. Compressor replacement, if the unit has sustained damage, is the most expensive scenario.