Error code reference

Sub-Zero Wine Storage Error Code 07

Lower cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temperatures.

SourceSub-Zero Service Manual: UW Undercounter Wine: Service Manualp. 2-16, 6-6, 6-7

Diagnostic procedure

The full 07 procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check lower compartment thermistor electrical connections and continuity from thermistor to J2 on control board; reconnect/repair connections. Check thermistor for 30,000 to 33,000 ohms at 32°F.

SourceSub-Zero Service Manual: UW Undercounter Wine: Service Manualp. 2-16, 6-6, 6-7

More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock 07 procedure $9.95

Or subscribe: $29/month for all codes plus Max diagnostics, with 70 Max messages a day. Plus applicable tax.

Where this code is documented

2 manuals in the MyPros+ library document this code for Sub-Zero wine storage.

Models covered by the manuals that document this code

More models are covered than are listed here.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax