U-Line Ice Maker Error Code Condenser T Open

Evaporator (condenser line out) thermistor circuit open.

Avg. service call
$285
National average. Trip fee plus diagnostic plus labor. Before parts.
MyPros+ 3-day pass
$9.95
Same diagnostic steps, on your phone. Start now.
You keep in your pocket
~$275
Even before you buy the part.
Skip the service call. Fix it yourself.
Full procedure unlocks instantly.
Get Started

What the Condenser T Open error code actually means

Your U-Line ice maker has detected a problem with a temperature sensor near the refrigerant line. The sensor either has a broken connection or has failed internally, so the machine cannot properly monitor its cooling system. Until this sensor issue is resolved, the ice maker will not operate normally.

Diagnostic procedure

The full Condenser T Open procedure

Step 1 is visible so you can confirm you are on the right page. The remaining steps, the ones that tell you whether to actually replace a part, unlock with any pass.

MyPros+ · DiagnosticsStep 1 preview
1
First diagnostic step
Check thermistor connection to harness for moisture or corrosion. Also check connection where thermistor harness attaches to main board. If connections are valid replace the thermistor.
More steps, wiring diagram references, and verified part numbers
Includes expected resistance and voltage values, connector pinouts, and supersession notes for replacement parts.
Unlock Condenser T Open procedure $9.95

Or subscribe: $29/month for unlimited access to all codes plus Max AI diagnostics.

Most common causes of Condenser T Open

Ranked by how often they cause this code
  1. 1Corroded or moisture-damaged thermistor connector
  2. 2Failed evaporator thermistor
  3. 3Loose or disconnected harness at the main board
  4. 4Damaged wiring in the thermistor harness
  5. 5Main control board fault

Most DIYers save hundreds by diagnosing before ordering parts.

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass

Questions people ask about Condenser T Open

What does Condenser T Open mean on a U-Line ice_maker?
Condenser T Open means the control board has detected an open circuit in the evaporator thermistor circuit located at the condenser line outlet. This sensor monitors refrigerant temperature, and an open circuit means the board is receiving no valid signal from it. The cause is typically a corroded connector, a loose harness connection, or a failed thermistor. The ice maker will not run normally until the fault is corrected.
Is the Condenser T Open error dangerous or urgent?
The error is not a safety hazard to people, but it does prevent the ice maker from operating correctly. Running the unit with an unmonitored refrigerant circuit could contribute to component wear over time. It is best to diagnose and correct the fault promptly rather than leaving the unit in a faulted state.
How much does it cost to repair a Condenser T Open error on a U-Line ice maker?
If the fix is simply cleaning or reseating a corroded connector, the repair may cost nothing beyond your time. Thermistor replacement parts typically range from around $20 to $60 depending on the specific model. If the main control board is the cause, board replacement costs can range from $150 to $350 or more for parts alone, plus labor if a technician is involved.
Can I fix the Condenser T Open error myself?
Yes, in many cases. Start by unplugging the unit and inspecting the thermistor connector and the harness connection at the main board for corrosion, moisture, or loose pins. Cleaning the connector or reseating the harness may resolve the fault without any parts. If connections are good, replacing the thermistor is a straightforward repair that a knowledgeable DIYer can typically handle.
Will resetting the ice maker clear the Condenser T Open error?
A reset may temporarily clear the fault code, but the error will return if the underlying problem is not fixed. Because the fault is triggered by a physical condition, either a bad connection or a failed thermistor, the control board will detect it again once the unit restarts. Address the wiring connections or replace the thermistor before relying on a reset.