U-Line Ice Maker Error Code Condenser T Open
Evaporator (condenser line out) thermistor circuit open.
Evaporator (condenser line out) thermistor circuit open.
First step from the service manual
Check thermistor connection to harness for moisture or corrosion. Also check connection where thermistor harness attaches to main board. If connections are valid replace the thermistor.
The complete diagnostic procedure includes additional test steps, resistance specifications, wiring diagram references, and component test points.
Get the full diagnostic procedure for Condenser T Open.
- Step-by-step tests with expected resistance, voltage, and continuity values
- Wiring diagram references and connector pinouts from the OEM service manual
- Verified part numbers when replacement is required
$29/month · Cancel anytime · Or $9.95 3-day pass
What Condenser T Open means on a U-Line ice maker
The "Condenser T Open" error on a U-Line ice maker indicates an open circuit condition in the evaporator thermistor circuit, specifically the sensor positioned on the condenser line outlet. This thermistor monitors refrigerant temperature at a critical point in the refrigeration cycle. When the control board detects that the thermistor circuit is open rather than reading a valid resistance, it triggers this fault code and halts normal operation to prevent damage to the refrigeration system.
An open circuit in the thermistor loop typically means the sensor itself has failed internally, or that the electrical connection between the thermistor and the main control board has been broken. Moisture and corrosion at the connector are among the most common culprits, particularly in ice maker environments where condensation is a constant factor. The wiring harness that runs from the thermistor to the board passes through areas exposed to humidity, making connector pins vulnerable to oxidation over time.
Diagnosis should begin at the physical connections before replacing any components. Inspect the thermistor connector for corrosion, moisture intrusion, or backed-out terminals. Then trace the harness to where it plugs into the main board and inspect that connection as well. If both connection points appear clean, secure, and undamaged, the thermistor itself has likely failed and requires replacement to restore normal operation.
Source: manufacturer service documentation.
Common causes of Condenser T Open
- 01
Corroded or moisture-damaged thermistor connector
Wiring / connectionIce maker environments expose wiring connectors to constant humidity and condensation. Oxidation or corrosion on the thermistor connector pins can break the circuit, triggering an open fault. Look for green or white buildup on the connector pins.
- 02
Failed evaporator thermistor
Part replacementThe thermistor itself can fail internally, causing a permanently open circuit regardless of connector condition. If connections are clean and secure, the thermistor is the most likely component to replace.
- 03
Loose or disconnected harness at the main board
Wiring / connectionThe connector where the thermistor harness plugs into the main control board can loosen over time due to vibration. Check that the harness is fully seated and latched at the board connection point.
- 04
Damaged wiring in the thermistor harness
Part replacementA break or nick in the wire insulation along the harness run can cause an open circuit. Inspect the full length of the wiring from the thermistor to the board for visible damage, pinching, or wear.
- 05
Main control board fault
Part replacementIf the thermistor and all wiring connections test good, a failure on the control board at the thermistor input circuit could produce an open fault reading. This is the least common cause and should be considered only after other components are ruled out.
Frequently asked questions about Condenser T Open
What does Condenser T Open mean on a U-Line ice_maker?
Can I fix the Condenser T Open error myself?
Is the Condenser T Open error dangerous or urgent?
Will resetting the ice maker clear the Condenser T Open error?
How much does it cost to repair a Condenser T Open error on a U-Line ice maker?