Model reference
GE PFDS450ELWW
Dryer
29 documents42 error codes45 service modes
Available documentation
Service Manual
- Profile Dryer with Steam Cycle Options62 pg
- New GE Profile Dryer UPVH880GJ78 pg
- Profile Gas and Electric Dryers Technical Service Guide64 pg
- GE Consumer Products Technical Service Guide Profile Gas and Electric Dryers63 pg
- GE Profile HE Dryer79 pg
- Profile Dryer DPVH880EJ DPVH880GJ Technical Service Guide68 pg
- Profile Dryer Technical Service Guide68 pg
- GE Consumer & Industrial Technical Service Guide - Profile Dryer68 pg
- Secadora Profile Servicio Guía de Técnico68 pg
- TECHNICAL SERVICE GUIDE DPGT750EC/GC GE Consumer Products Profile Gas and Electric Dryers63 pg
- Profile Dryer With Steam Technical Service Guide50 pg
- Technical Service Guide45 pg
- GE Profile High-Efficiency Dryer Technical Service Guide40 pg
- GE Profile HE Dryer16 pg
- Profile Dryers Owner's Manual32 pg
- GE Profile 7.3 Cu. Ft. Stainless Steel Capacity Steam Dryer Technical Service Guide41 pg
- Profile Stainless Steel Drum Gas and Electric Dryers with Steam - Technical Service Guide45 pg
- Pages from 31 9104 Profile Gas _ Electric Dryer DPGT750EC1WW3 pg
- GE Profile HE Dryer DPGT650E/G79 pg
- Profile Gas and Electric Dryers Technical Service Guide63 pg
- Profile Stainless Steel Gas and Electric Dryers Technical Service Guide45 pg
Bulletin
- GWS2011 Profile HA Dryer Upgrade – PFDS450/455 Series GE Profile 7.5 cu. ft. stainless steel capacity frontload dryer with Steam53 pg
Training
- Profile HA Dryer Upgrade – PFDS450/455 Series GE Profile 7.5 cu. ft. stainless steel capacity frontload dryer with Steam53 pg
- Profile HA Dryer88 pg
- Profile HA Dryer78 pg
- Profile HA Dryer Upgrade – PFDS450/455 Series53 pg
Installation Guide
- GE Profile Harmony Dryer - Dimensions and Installation Information3 pg
- GE Profile Dryer DPGT750GC2PL Owners Manual88 pg
Other
- PFDS450ProfileDryerwSteam53 pg
MyPros+ Max
Diagnose your GE PFDS450ELWW.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (42)
CodeMeaning
Blocked AirflowBlower speed detected at or above 3000 RPM for over 30 seconds; dryer will stop…Blower not speeding upDuring initial warm-up, the blower failed to reach the minimum speed necessary…CLgDuct/vent blockage detected; dryer will continue to operate but display may…dEDoor switch errorDoor Switch Stuck ClosedAn attempt has been made to start a cycle after 3 or more consecutive cycles…Door Switch Stuck OpenThe dryer did not detect the door was closed within 5 minutes of displaying…E0No errors logged in the fault log.E00No error codes present.E02Open or shorted moisture sensing rod.E1Interface EEPROM reading or writing improperly.E10Blower motor is not rotating properly.E101Power EEPROM reading or writing improperly.E11Blocked airflow detected.E12Drum motor is not rotating properly or centrifugal switch is bad.E16LIN communication failure between the machine control and the UI control.E17VFD communication errorE18Stuck button/keys detected.E2Inlet thermistor shorted.E3Outlet thermistor shorted.E4Inlet thermistor open.E5Steam pump error.E50EEPROM failure (electronic control error).E6Door switch malfunction.E60Door switch has not opened during the last 3 consecutive completed cycles.E61Input voltage too high.E62Outlet thermistor shorted.E81No model select connector detected.EEEEPROM errorFlame Detector / IgnitorUsing the feedback signal from the flame detector, the control has detected the…Flash ROM EEPROMChecksum errors found; data is not being stored correctly in controlView all 42 error codes
Gas Setup FailedThe control determined the heat level output does not match the model connector…HeaterNo heating detected by either thermistor even though the control turned the…Inlet ThermistorInlet thermistor reading is out of expected range; dryer defaults to…Keypanel MembraneControl sensed a keypanel membrane pad pressed for longer than 30 seconds; unit…LCD Display TouchscreenControl sensed an LCD display touchscreen input for longer than 30 seconds…Model Connector FailedThe control determined the model connector plug is missing on a gas dryer or a…Moisture SensorControl has determined the moisture sensor rods are shorted; dryer will operate…Outlet ThermistorOutlet thermistor reading is out of expected range; heater will be limited to…PSHigh voltage error.Serial Washer and Dryer ConnectionDryer has not received a proper response from the washer after 3 attempts…tEThermistor outlet errortE4Steam generator thermistor error.
Service modes (45)
- Control Lock["Press and hold Dry Level and Temp buttons simultaneously for 3 seconds.","Display shows 'cl' when…
- diagnostic_steam_test_dryerSame service test mode as 880 units (found in pub 31-9167) with the addition of a steam generator…
- diagnostic_steam_test_washerEnter diagnostic mode and select 'Steam Test'.
- Duct Condition Test["Ensure dryer is in idle state with no load in the drum.","Press DAMP ALERT and TEMP buttons…
- Factory Test Mode["Press POWER to turn the dryer on
- Field Service Mode["Press POWER to turn the dryer on.","If the home screen is displayed, proceed to next step
- Sales Demo Mode["Press HOME and MY CYCLES simultaneously for 3 seconds."]
- Service Mode["Ensure the dryer is in idle state (no display on SSD).","Press and hold 'Less Time' and 'Wrinkle…
- Service Mode (Field Service Mode)["1
- Service Test Mode["Ensure power is connected and dryer is in idle state (all LCD and LED indicators off).","Press…
- service_mode_washer_heater_relay_testEnter Service Mode to test the tub heater and heater relay.
- Setup/Self Diagnostic Mode["After repairs from field service mode, disconnect power and reconnect power.","The unit will…
- t1 - Dryer ModelNavigate to t1 using cycle selection knob, press START/PAUSE.
- T1 - LED Component Check["Enter Service Mode (display shows 't1').","Press Start button
- T1 – LED Component Check["Enter Service Mode (display shows 't1').","Press Start to begin test.","Display toggles between…
- T2 - Software Revision["Navigate to t2 using Cycles button.","Press Start
- t2 - Software/EEPROM VersionNavigate to t2 using cycle selection knob, press START/PAUSE.
- T2 – Software Revision["Navigate to T2 using Cycles button.","Press Start to begin test.","Display toggles between…
- t3 - CRC CheckNavigate to t3 using cycle selection knob, press START/PAUSE.
- T3 - Dryer Motor Test["Navigate to t3 using Cycles button.","Press Start
- T3 – Dryer Motor Test["Navigate to T3 using Cycles button.","Press Start to begin test.","Display shows '00' and drum…
- T4 - Door Switch Test["Navigate to t4 using Cycles button.","Press Start
- t4 - User Interface TestNavigate to t4 using cycle selection knob, press START/PAUSE.
- T4 – Door Switch Test["Navigate to T4 using Cycles button.","Press Start to begin test.","Display shows 'dE' if door is…
- t5 - Error CodesNavigate to t5 using cycle selection knob, press START/PAUSE.
- T5 - Humidity Sensor Test (Sensor Rods)["Navigate to t5 using Cycles button.","Press Start
- T5 – Humidity Sensor Test["Navigate to T5 using Cycles button.","Press Start to begin test.","Display shows a value from 30…
- T6 - Heater 1 and Outlet Thermistor Test["Navigate to t6 using Cycles button.","Press Start
- t6 - Outlet ThermistorNavigate to t6 in service test mode, press START/PAUSE.
- t6 - Outlet Thermistor TestNavigate to t6 using cycle selection knob, press START/PAUSE.
- T6 – Heater 1 and Outlet Thermistor Test["Navigate to T6 using Cycles button.","Press Start to begin test.","Heater 1 turns on.","Display…
- T7 - Heater 1 and Heater 2 (Gas On) Test["Navigate to t7 using Cycles button.","Press Start
- t7 - Inlet ThermistorNavigate to t7 in service test mode, press START/PAUSE.
- t7 - Inlet Thermistor TestNavigate to t7 using cycle selection knob, press START/PAUSE.
- T7 – Heater 1 and Heater 2 Test["Navigate to T7 using Cycles button.","Press Start to begin test.","Heater 1 and Heater 2 both…
- T8 - Error Codes["Navigate to t8 using Cycles button.","Display shows 't8' then shows the last error code saved by…
- t8 - Moisture SensorNavigate to t8 in service test mode, press START/PAUSE.
- t8 - Moisture Sensor TestNavigate to t8 using cycle selection knob, press START/PAUSE.
- T8 – Error Codes (Stored Fault History)["Navigate to T8 using Cycles button.","Display shows 't8' then the last saved error code for 1…
- t9 - Door Open/ClosedNavigate to t9 in service test mode, press START/PAUSE.
- t9 - Door Open/Closed TestNavigate to t9 using cycle selection knob, press START/PAUSE.
- tA - Brownout SignalNavigate to tA in service test mode, press START/PAUSE.
- tA - Brownout Signal TestNavigate to tA using cycle selection knob, press START/PAUSE.
- tb - Water Valve TestNavigate to tb using cycle selection knob, press START/PAUSE.
- tc - Restore EEPROMNavigate to tc using cycle selection knob, press START/PAUSE.
Full entry steps, exit procedures, and test sequences are available in Max.
Related GE dryer models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass