Model reference
Whirlpool GGE388LXS03
Range
2 documents14 error codes10 service modes
Available documentation
Tech Sheet
- Whirlpool Oven GGE388LXS01 Tech Sheet16 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
MyPros+ Max
Diagnose your Whirlpool GGE388LXS03.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (14)
CodeMeaning
E0 F1EEPROM communication error (internal control failure).E0 F3Upper oven main temperature sensor open or shorted.F1Control failure or UL A/D error(s) detected in the control board.F1 E*Control board failure (all F1 sub-codes indicate control fault).F2Shorted/stuck key detected on the control keypad.F3Oven sensor opened or oven sensor shorted.F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F6 E*Control communication failure.F9House miswiredService modes (10)
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Semi Automatic TestEnter Diagnostics Mode first (CANCEL > CANCEL > START within 5 seconds)
- Temperature CalibrationPress SETTINGS/OPTIONS until 'Temp Calib' is highlighted, then follow on-screen instructions
- Test ModeEnter Diagnostics Mode first (CANCEL > CANCEL > START within 5 seconds)
Full entry steps, exit procedures, and test sequences are available in Max.