Model reference
Whirlpool WFE975H0HV4
Range
11 documents26 error codes29 service modes
Available documentation
Tech Sheet
- Service Technical Sheet W11326979B2 pg
- Tech Sheet - W11326979 - Rev B2 pg
- Tech Sheet44 pg
- Tech Sheet44 pg
Service Manual
- Tech Manual36 pg
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
Bulletin
- Installation Pointer - W11663212 - Rev B - New Terminal Block for Tulsa FSR6 pg
Service Flash
- Installation Pointer - W11729886 - Rev A - Powercord Requirements6 pg
Tech Tip
- Oven Cleaning Quick Reference Guide2 pg
Quick Reference
- Quick Start Guide3 pg
- Freestanding Electric Range Control Guide32 pg
MyPros+ Max
Diagnose your Whirlpool WFE975H0HV4.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (26)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1E0EEPROM Communication ErrorF1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F1E9WIDE queue full.F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2E0Keypad DisconnectedF2E1Stuck KeypadF2E2Cancel key error.F3E0Main Oven Sensor Open or ShortedF3E1Oven sensor shorted (LCC/LCX control).F3E2Warming drawer sensor open or shorted.F3E3Clean range over temperature (LCC/LCX control).F5E0Door and door position switch do not agree (Clean modeF5E1Door latch not operating during Clean mode (LCC/LCX control).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Oven TempF6E2Over temperature during clean mode (Maxwell/MRC control).F6E3Over temperature in warming drawer.F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9E0MiswiredService modes (29)
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Automatic Diagnostic Test)Enter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds)
- Auto Test (Automatic Test Mode)Enter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds)
- Auto Test (Maxwell/MRC Controls)1
- Clear all error codesPress CANCEL > CANCEL > START within 5 seconds
- Clear error codesEnter Diagnostics mode by pressing CANCEL>CANCEL>START within 5 seconds
- Clear Fault CodesEnter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds)
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- Control ResetFrom Diagnostics Mode, press number 3 or 6 keypads until 'Control Reset' is displayed, then press…
- Diagnostics modePress CANCEL > CANCEL > START within 5 seconds.
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics submenusAfter entering Diagnostics mode, press the number 3 or 6 keypads to navigate through submenus
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- Fault Code ClearingEnter Diagnostics mode by pressing CANCEL>CANCEL>START within 5 seconds
- Fault Code Viewing and ClearingFrom Diagnostics Mode, press number 3 or 6 keypads until 'Faults' is displayed, then press Start
- Fault Code Viewing/ClearingEnter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds)
- Manual Relay Test ModeEnter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds). Press the number 3 or 6 keypads…
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature CalibrationPress Settings or Options keypad until 'Temp Calib' is displayed
- Test Mode (Manual Relay Activation)Enter Diagnostics mode (CANCEL>CANCEL>START within 5 seconds)
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
Full entry steps, exit procedures, and test sequences are available in Max.