Model reference
Whirlpool WFG745H0FH0
Range
8 documents25 error codes31 service modes
Available documentation
Tech Sheet
- tech-sheet-W10841359-RevA.pdf8 pg
- Wiring Diagram - W10843089 - Rev A2 pg
- Tech Sheet - W10843073 - Rev A8 pg
Service Manual
- SERVICE MANUAL - Whirlpool®, Maytag®, KitchenAid®, Kenmore®, JennAir®, IKEA®, and Amana® Ranges104 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
Bulletin
- DIP - W107149136 pg
Tech Tip
- Instruction Sheet4 pg
Installation Guide
- Installation Instructions40 pg
MyPros+ Max
Diagnose your Whirlpool WFG745H0FH0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
F1EEPROM communication error or internal control failure (Maxwell/MRC control).F1E0EEPROM communication error.F1E1A/D error (LCC/LCX control).F1E2A/D error (LCC/LCX control).F1E5Sensor out of range.F1E7Circuit board thermistor open or short-circuited.F2Keypad disconnected, stuck key, or cancel key error (Maxwell/MRC control).F2E0Keypad disconnected.F2E1Key stuck.F2E2Cancel key error.F3E0Main oven sensor open or short-circuited.F3E1Oven sensor shorted (LCC/LCX control).F3E2Warming drawer sensor open or short-circuited.F3E3Clean range over temperature (LCC/LCX control).F5E0Door and door switch mismatch (clean mode, on certain models).F5E1Door latch not functional (clean mode, on certain models).F5E2Door and door position switches do not agree during Clean mode (LCC/LCX…F6E0Oven User Interface lost communication between UI and ACU (Indigo control).F6E1Bake mode excessive temperature (overheating).F6E2Clean mode excessive temperature (overheating).F6E3Warming drawer excessive temperature (overheating).F6E4Oven User Interface UI and ACU state status mismatch (Indigo control).F8E0Cooling fan speed too lowF8E2Cooling fan speed too highF9E0Mis-wired house or range (Maxwell/MRC control).Service modes (31)
- Auto Test["Enter Diagnostics mode (CANCEL > CANCEL > START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test - Maxwell/MRC Controls["Enter Diagnostics Mode (CANCEL>CANCEL>START)","Press the 'up' arrow, '+' key, or '3' key to…
- Auto Test (Maxwell/MRC Controls)1
- Component Activation (Indigo Controls)From Diagnostics Menu, select Component Activation
- CONTROL RESETFrom diagnostic mode, scroll to CONTROL RESET (step 6).
- Diagnostics Mode - Indigo Controls (Option 1)["Press HOME>FAVORITES>LIGHT (repeat this sequence three times in a row)","The warning will be…
- Diagnostics Mode - Indigo Controls (Option 2)["Press TOOLS>INFO>SERVICE AND SUPPORT","Press the Diagnostics button for 1 minute","Press…
- Diagnostics Mode - LCC/LCX Controls["Press CANCEL","Press CANCEL","Press START (all within a 5-second period)","Initial display shows…
- Diagnostics Mode - Maxwell/MRC Controls["Press CANCEL","Press CANCEL","Press START (all within quick succession)","Display shows 'TEST ON'…
- Diagnostics Mode (Indigo Controls) - Option 1Press HOME > FAVORITES > LIGHT, repeat three times in a row
- Diagnostics Mode (Indigo Controls) - Option 2Press TOOLS > INFO > SERVICE AND SUPPORT
- Diagnostics Mode (LCC/LCX Controls)Press CANCEL > CANCEL > START within a 5-second period. Scroll through settings with up arrow…
- Diagnostics Mode (Maxwell/MRC Controls)Press CANCEL > CANCEL > START within 5 seconds
- Diagnostics Mode (Service Mode Entry)["Press CANCEL","Press CANCEL","Press START","Display shows 'TEST ON' with cavity temperature and…
- Diagnostics Test Mode Relay Checks (LCC/LCX Controls)While in Diagnostics Mode
- DISPLAYFrom diagnostic mode, scroll to DISPLAY (step 5).
- ENG MODE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to service mode 2
- ENG MODE (Engineering Mode)From diagnostic mode, scroll to ENG MODE (step 2)
- FAULTSFrom diagnostic mode, scroll to FAULTS (step 7).
- MRC Control Module Diagnostic ModePress CANCEL, then CANCEL, then START
- RELAY USAGEFrom diagnostic mode, scroll to RELAY USAGE (step 8).
- Service Modes - Maxwell/MRC Controls (TEST ON, USAGE, ENG MODE, TEST MODE, VERSION, DISPLAY, FAULTS, EXTERNAL FAULTS, RELAY USAGE, AUTO TEST)["Press CANCEL>CANCEL>START to enter Service Mode","Use up arrow/+ key/3 key to scroll through…
- Service Modes Menu (Maxwell/MRC Controls)Press CANCEL>CANCEL>START. Scroll through modes using up arrow/'+'/3 key
- Temperature Adjustment["Press OVEN LIGHT for 5 seconds (current offset or 0° is shown)","Press 'More'/'Less' arrow keys…
- TEST MODE["Enter Diagnostics mode (CANCEL > CANCEL > START)","Scroll to service mode 3
- TEST MODE (Relay Control)From diagnostic mode, scroll to TEST MODE (step 3)
- TEST ON - Relay Checks (Maxwell/MRC Controls)From Diagnostics Mode (CANCEL>CANCEL>START), at TEST ON display
- TEST ON (Relay Checks)["Enter Diagnostics mode (CANCEL > CANCEL > START)","Upon entry, 'TEST ON' is displayed","Press…
- TEST ON (Relay Control)Available immediately upon entering diagnostic mode (CANCEL>CANCEL>START)
- USAGEFrom diagnostic mode, press up arrow/'+' or '3' once to scroll to USAGE mode.
- VERSIONFrom diagnostic mode, scroll to VERSION (step 4).
Full entry steps, exit procedures, and test sequences are available in Max.
Related Whirlpool range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass